Applications
MPRX® FLEXISHIP type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. MPRX® FLEXISHIP using is recommended for installations in narrow space, and in particular for connexions.
Bending force is reduced by 30% to compare with MPRX® cable.
MPRX® FLEXISHIP type withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements.
1. Conductor
Flexible bare copper
class 5
• sector-shaped for 3 cores with cross section ≥ 70 mm2
2. Insulation
XLPE
(cross linked polyethylene)
3. Outer sheath
(Filler if necessary)
Polyolefin SHF1
Colour: black
SHF2 on request
Core identification
1 core: black
2 cores: brown - blue
3 x: brown-black - grey
3G: brown-blue-green/yellow
4x: brown-black-grey-blue
4 G : brown-black-grey-green/yellow
5G: brown-black-grey-green/yellow-blue
Minimum Bending Radius for fixed installations : 4 x outer diameter
Test Voltage: 3.5 kV AC between cores
"S" in dimensional data : Sector shaped conductor
|