Description
Normes
Internationales : IEC 60092-350; IEC 60092-360; IEC 60092-376; IEC 60228; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034Description
Application
MPRXCX® type is used on board of ships for fixed installations complying with IEC 60092-352.
The good screening qualities of the braid also reduce radio interference and electrical influences to electronic installations. MPRXCX® type withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements.
All materials used to manufacture this cable are halogen-free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships.
Design
1. Conductor
Stranded bare copper, class 2
2. Insulation
XLPE
(Cross-linked polyethylene)
3. Inner covering
(Filler, if necessary)
Lapped
5. Armouring
Bare copper braid
6. Outer Sheath
Polyolefin SHF1
Colour: grey
(SHF2 on request)
Marking
I NEXANS I MPRXCX 150/250V "n" x "s" mm² 150/250V 90C
IEC 60092-376 IEC 60332-3-22 Cat.A "ww/yy" *CE* + metric marking
Core Identification
white with printed number
Caractéristiques
Caractéristiques de construction | |
---|---|
Sans halogène | IEC 60754-1 |
Couleur de la gaine | Gris |
Caractéristiques électriques | |
Tension de service nominale Uo/U (Um) | 150 / 250 (300) V |
Caractéristiques d'utilisation | |
Non propagateur de l incendie | IEC 60332-3-22 |
Non propagateur de la flamme | IEC 60332-1 |
Faible dégagement de fumée | IEC 61034 |
Toxicité de la fumée | Non |
Corrosivité des fumées | IEC 60754-2 |
Température maximale sur l'âme | 90°C |
Résistance aux interférences électromagnétiques | Oui |
Caracteristiques spécifiques | |
See all products | |
|