NF C33-210 connection cables

Products

H1-XDV-AU 2x35 NEW

Nexans ref. 10044003 - Country ref. 01416220

  • Packaging: Cut to length (m)
  • Number of phases: 1
  • Conductor cross-section: 35 mm²
  • Number of cores: 2

 

H1-XDV-AU 3x16 +16 NEW

Nexans ref. 10057261 - Country ref. 01416700

  • Packaging: Cut to length (m)
  • Number of phases: 3
  • Conductor cross-section: 16 mm²
  • Number of cores: 4

 

H1-XDV-AU 3x25 +25 NEW

Nexans ref. 10057406 - Country ref. 01416710

  • Packaging: Cut to length (m)
  • Number of phases: 3
  • Conductor cross-section: 25 mm²
  • Number of cores: 4

 

H1-XDV-AU 3x35 +35 NEW

Nexans ref. 10044004 - Country ref. 01416720

  • Packaging: Cut to length (m)
  • Number of phases: 3
  • Conductor cross-section: 35 mm²
  • Number of cores: 4

 

Description

Description

Standards

  • National
    NF C33-210

Service connection single phase and three phase cables

Application

Low voltage buried cables for connection public networks.

Characteristics

The three phase conductors are made of either circular solid or stranded aluminum.

The neutral conductor made of solidor stranded aluminum is circular and sheathed with lead.

The watertightness between the lead sheath is made with a waterproof material only on single phase cables. On three-phase cables it can be made on demand.

Stranding

The phase conductors and neutral are assembled in a way, which makes them easy to separate to splice with branching wires.

Over the phase and neutral conductors, a galvanized steel armour is wound in direct contact with the lead sheath. This construction is then sheathed with PVC, with high mechanical properties.

Filler : PVC for single phase cable except 50 mm2 and three phase cable 16 mm2.

Sheath : on demand, antitermite treatment possible on demand.

Marking

  • H1 XDV-AU NxS1 + 1xS2 MINIDISTRICABLE® 211 NF C33-210 «manufacturing number/manufacturing year» «metric marks/manufacturing date».​
  • N : number of phase conductors,
  • S1 : cross section of phase conductors,
  • S2 : cross section of neutral conductor.

 

Electrical characteristics

Rated Voltage : 0.6/1 kV.

Test Voltage : 3.5 kV for 15 minutes.

Resistance of the sheath to voltage surges : 1.2/50 µs with positive or negative polarity and a peak value of 20 kV.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Pilot wires
None
Conductor flexibility
Solid class 1
Conductor material
Aluminum
Conductor shape
Circular solid (RE)
Insulation
XLPE (chemical)
Outer sheath
PVC
Screen
Two unlapped galvanized mild steel tapes
Sheath colour
Black

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Resistant to termites
No
Packaging
Cut to length

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close