FLAMEX® FIRE RESISTANT WTB-MVB & CAN BUS 120 Ω
FLAMEX CAN BUS 1x2x0.5² + 1x0.5²
Nexans ref. 2PM590
- Packaging: Drum (1000m)
- Construction type: 1x2x0,5 + 1x0,5
- Minimum cable diameter: 9.8 mm
- Maximum cable diameter: 10.2 mm
- Approximate weight: 125 kg/km
FLAMEX MVB 1x2x0.5²
Nexans ref. 2PM599
- Packaging: Drum (1000m)
- Construction type: 1x2x0,5
- Minimum cable diameter: 9.5 mm
- Maximum cable diameter: 10 mm
- Approximate weight: 122 kg/km
FLAMEX MVB 4x0.5²
Nexans ref. 2PM600
- Packaging: Drum (1000m)
- Construction type: 4x0,5
- Minimum cable diameter: 10.8 mm
- Maximum cable diameter: 11.2 mm
- Approximate weight: 135 kg/km
FLAMEX WTB 1x2x0.75²
Nexans ref. 2PM601
- Packaging: Drum (1000m)
- Construction type: 1x2x0,75
- Minimum cable diameter: 11.3 mm
- Maximum cable diameter: 11.7 mm
- Approximate weight: 160 kg/km
Description
Description
Standards
-
InternationalEN 45545-2 (HL3); EN 50200
Fostering innovation, Nexans designed FLAMEX® EN 50200 Communication cables that can reach data transmission performances for Category 5E or 6A as described in the ISO/CEI 11801, showing no loss of data train and no drop of the transmission parameters when burnt. This unique fire performance is achievable thanks to our technology for fire resistant cables known as INFITTM. On top of the fire performances, this technology makes easier and faster the preparation and the connection of the wires with rolling stock connectors compared to older taping technologies. FLAMEX® EN 50200 MVB, WTB and CAN BUS cables are fire retardant, low smoke and halogen-free satisfying performance requirements from EN 45545-2.
DESIGN
- Conductor: Flexible stranded tinned copper in metric or American wire gauge (AWG) sizes
- Insulation: Special halogen-free INFITTM fire proof material
- Screen: Tinned copper braid. Optional aluminum/ polyester or separator tapes
- Outer sheath: Cross-linked compound type EM 104 or EM 101 acc. to EN 50264- 1 Oil, diesel, ozone and UV resistant. Colour: red
Example of marking:
FIRE SAFETY STANDARDS
FLAMEX® communication cables are conform to EN 45545-2.
Fire resistant acc. to:
- EN 50200 PH 30-60 tested under 110 V
- EN 50200 PH 90 Ethernet frame loss and transmission parameter
BENDING RADIUS
Static use: 8 x outer diameter
For installation and occasional movements: 10 x outer diameter
GUIDE TO USE
Cabling rules are given in EN 50343.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania