MEPRXCX® FLEXISHIP® 8.7/15 (17.5) kV

Products

MEPRXCX® FLEXISHIP® 8,7/15kV 1x35

Nexans ref. 25499514

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 35 mm²
  • Minimum outer diameter: 27.0 mm
  • Maximum outer diameter: 30.5 mm
  • Approximate weight: 1180 kg/km
  • Permissible current rating in open air: 157 A

 

MEPRXCX® FLEXISHIP® 8,7/15kV 1x50

Nexans ref. 10218154

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 50 mm²
  • Minimum outer diameter: 28.0 mm
  • Maximum outer diameter: 31.0 mm
  • Approximate weight: 1431 kg/km
  • Permissible current rating in open air: 196 A

 

MEPRXCX® FLEXISHIP® 8,7/15kV 1x70

Nexans ref. 10263318

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 70 mm²
  • Minimum outer diameter: 30.0 mm
  • Maximum outer diameter: 33.5 mm
  • Approximate weight: 1689 kg/km
  • Permissible current rating in open air: 242 A

 

MEPRXCX® FLEXISHIP® 8,7/15kV 1x95

Nexans ref. 10218158

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 95 mm²
  • Minimum outer diameter: 33.0 mm
  • Maximum outer diameter: 36.5 mm
  • Approximate weight: 2008 kg/km
  • Permissible current rating in open air: 293 A

 

MEPRXCX® FLEXISHIP® 8,7/15kV 1x120

Nexans ref. 10251351

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 120 mm²
  • Minimum outer diameter: 34.0 mm
  • Maximum outer diameter: 38.0 mm
  • Approximate weight: 2322 kg/km
  • Permissible current rating in open air: 339 A

 

MEPRXCX® FLEXISHIP® 8,7/15kV 1x150

Nexans ref. 10218162

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 150 mm²
  • Minimum outer diameter: 35.0 mm
  • Maximum outer diameter: 39.0 mm
  • Approximate weight: 2751 kg/km
  • Permissible current rating in open air: 389 A

 

MEPRXCX® FLEXISHIP® 8,7/15kV 1x185

Nexans ref. 10251352

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 185 mm²
  • Minimum outer diameter: 38.5 mm
  • Maximum outer diameter: 43.0 mm
  • Approximate weight: 3104 kg/km
  • Permissible current rating in open air: 444 A

 

MEPRXCX® FLEXISHIP® 8,7/15kV 1x240

Nexans ref. 10218166

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 240 mm²
  • Minimum outer diameter: 41.5 mm
  • Maximum outer diameter: 46.0 mm
  • Approximate weight: 3803 kg/km
  • Permissible current rating in open air: 522 A

 

MEPRXCX® FLEXISHIP® 8.7/15kV 3x35

Nexans ref. 10284305

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 35 mm²
  • Minimum outer diameter: 52.5 mm
  • Maximum outer diameter: 58.0 mm
  • Approximate weight: 4540 kg/km
  • Permissible current rating in open air: 110 A

 

MEPRXCX® FLEXISHIP® 8.7/15kV 3x50

Nexans ref. 10284304

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 50 mm²
  • Minimum outer diameter: 56.5 mm
  • Maximum outer diameter: 62.0 mm
  • Approximate weight: 5392 kg/km
  • Permissible current rating in open air: 137 A

 

MEPRXCX® FLEXISHIP® 8,7/15kV 3x70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 70 mm²
  • Minimum outer diameter: 61.0 mm
  • Maximum outer diameter: 66.0 mm
  • Approximate weight: 6820 kg/km
  • Permissible current rating in open air: 169 A

 

MEPRXCX® FLEXISHIP® 8.7/15kV 3x95

Nexans ref. 10045593

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 95 mm²
  • Minimum outer diameter: 65.5 mm
  • Maximum outer diameter: 71.5 mm
  • Approximate weight: 7471 kg/km
  • Permissible current rating in open air: 205 A

 

MEPRXCX® FLEXISHIP® 8,7/15kV 3x120

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 120 mm²
  • Minimum outer diameter: 70.0 mm
  • Maximum outer diameter: 76.5 mm
  • Approximate weight: 8435 kg/km
  • Permissible current rating in open air: 237 A

 

MEPRXCX® FLEXISHIP® 8.7/15kV 3x150

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 150 mm²
  • Minimum outer diameter: 73.0 mm
  • Maximum outer diameter: 80.0 mm
  • Approximate weight: 9631 kg/km
  • Permissible current rating in open air: 272 A

 

Description

Description

Standards

  • International
    IEC 60092-350; IEC 60092-354; IEC 60092-360; IEC 60228; IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

 

Application

MEPRXCX® FLEXISHIP®   8.7/15 kV armoured power cables are used for critical medium voltage systems where enhanced mechanical protection and electrical screening (EMC) is required. These products are recommended for installations and connections in environments where an optimal bending radius is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.
MEPRXCX® FLEXISHIP® 8.7/15 kV cables are compatible with Nexans`medium voltage accessories to connect generators, switchgears and transformers.

 

Design

1.    Conductor
      
Flexible bare copper, class 5

2.    Extruded semi-conducting layer

3.    Insulation
       EPR (Ethylene-propylene rubber)

4.    Screen
       Extruded semi-conducting layer
       Concentric layer of copper wires

5.    Inner covering
       Halogen-free polyolefin

6.    Armouring
       Bare copper braid

7.    Outer sheath
       Polyolefin SHF1 (SHF2 on request)
       Colour: red

 

Marking

I NEXANS I MEPRXCX FLEXISHIP 8.7/15 (17.5) kV  "n" x "s" mm8.7/15 (17.5) kV
90°C  IEC 60092-354 IEC 60332-3-22 "ww/yy" + metric marking

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Sheath colour
Red

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3-22
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Electro magnetic interference resistance
Yes
Operating temperature, range
-30 ... 80 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close