Description
Standards
International : EN 50525-2-21National : NF C 32-102-4
Description
Application
Flexible cable of 2 to 5 cores for the power supply of mobile or semi-mobile appliances submitted to low mechanical stress (houshold electricals-portable tooling...) Especially suitable for the stripping force on automatic machines and for low temperature environments.
Design
1. Conductor
Flexible bare or tinned copper Class 5.
2. Insulation
-Special crosslinked elastomer EI7
3. Outer sheath
- Special crosslinked elastomer EM6
- Colour black
- Other colours on request
Core colours
- 2 cores (X) = Brown + Blue
- 3 cores (G) = Green-Yellow + Brown + Blue
- 3 cores (X) = Brown + Black + Grey
- 4 cores (G) = Green-Yellow + Brown + Black + Grey
- 4 cores (X) = Blue + Brown + Black + Grey
- 5 cores (G) = Green-Yellow + Blue + Brown + Black + Grey
- 5 cores (X) = Blue + Brown + Black + Grey + Black
Marking
USE HAR H05BB-F nb (x ou G) S mm² 269 NEXANS
Nota
For any request of specific cables, please join our contact team :
Copper conductors, specific insulations and assemblies…
Outersheath : diameter, color, marking, unsheathing on automatic machines…
Packing on request…
Adapted delivery time…
Characteristics
Construction characteristics | |
---|---|
Sheath colour | Black |
Conductor flexibility | Flexible class 5 |
Conductor material | Bare copper |
Outer sheath | Elastomer |
Halogen free | IEC 60754-1 |
Dimensional characteristics | |
Number of cores | 5 |
Conductor cross-section | 1mm² |
Approximate weight | 125kg/km |
Average insulation thickness | 0.6mm |
Average sheath thickness | 1.0mm |
Minimum outer diameter | 8.5mm |
Nominal outer diameter | 8.7mm |
Maximum outer diameter | 8.9mm |
Electrical characteristics | |
Maximum permissible nominal current | 17A |
Max. DC resistance of the conductor at 20°C | 19.5Ohm/km |
Voltage drop, single phase | 34.1V/A.km |
Rated Voltage Uo/U (Um) | 300 / 500 V |
Mechanical characteristics | |
Cable flexibility | Flexible |
Usage characteristics | |
Chemical resistance | Accidental |
Smoke density | IEC 61034 |
Gases corrosivity | IEC 60754-2 |
Max. conductor temperature in service | 90°C |
Packaging | Drum |
Operating temperature, range | -40 .. 75°C |
Gases toxicity | BS 6425, IEC 60754, EN 50267 |
Short-circuit max. conductor temperature | 200°C |