Nexans PV H1Z2Z2-K Energyflex Cable (1.5kV DC)

Produits

ENERGYFLEX® 1x4mm²

Réf. Nexans 10189494

  • Conditionnement: Touret (m)
  • Couleur de la gaine: Black (blue or red stripe on request)
  • Section du conducteur: 4 mm²

 

ENERGYFLEX® 1x4mm² D500

Réf. Nexans 10191003

  • Conditionnement: Touret (500m)
  • Couleur de la gaine: Black (blue or red stripe on request)
  • Section du conducteur: 4 mm²

 

ENERGYFLEX EN50618 1x4 ONE Stripe RG D500

Réf. Nexans 10206312

  • Conditionnement: Touret (m)
  • Couleur de la gaine: Noir liseré rouge
  • Section du conducteur: 4 mm²

 

ENERGYFLEX® 1x6mm²

Réf. Nexans 10189495

  • Conditionnement: Touret (m)
  • Couleur de la gaine: Black (blue or red stripe on request)
  • Section du conducteur: 6 mm²

 

ENERGYFLEX® 1x6mm² D500

Réf. Nexans 10191094

  • Conditionnement: Touret (500m)
  • Couleur de la gaine: Black (blue or red stripe on request)
  • Section du conducteur: 6 mm²

 

ENERGYFLEX 1X6 EN50618 One Stripe RG D500

Réf. Nexans 10206375

  • Conditionnement: Touret (m)
  • Couleur de la gaine: Noir liseré rouge
  • Section du conducteur: 6 mm²

 

ENERGYFLEX® 1x10mm²

Réf. Nexans 10191044

  • Conditionnement: Touret (m)
  • Couleur de la gaine: Black (blue or red stripe on request)
  • Section du conducteur: 10 mm²

 

ENERGYFLEX® 1x10mm² D500

Réf. Nexans 10191000

  • Conditionnement: Touret (500m)
  • Couleur de la gaine: Black (blue or red stripe on request)
  • Section du conducteur: 10 mm²

 

ENERGYFLEX® 1x16mm² D500

Réf. Nexans 10185635

  • Conditionnement: Touret (500m)
  • Couleur de la gaine: Black (blue or red stripe on request)
  • Section du conducteur: 16 mm²

 

Description

Description

Normes

  • Normes internationales
    EN 50618; IEC 62930

Application

Les câbles ENERGYFLEX® sont adaptés à une utilisation extérieure permanente à long terme dans des conditions climatiques variables et difficiles. Ils sont conçus et testés pour fonctionner à une température maximale normale du conducteur de 90°C et pendant 20 000 heures jusqu'à 120°C. Par conséquent, la durée de vie prévue dans des conditions normales d'utilisation est de 30 à 40 ans (selon le diagramme d'Arrhenius).
Ces derniers câbles ENERGYFLEX® de 1,5 kV DC offrent des performances exceptionnelles, une facilité d'installation et une fiabilité durable pour les parcs solaires. Dans les véritables centrales solaires ou sur les toits, ils interconnectent les panneaux solaires et les relient également à la boîte de dérivation (si elle existe) ou, si nécessaire, à l'onduleur.

  • Marque
  ENERGYFLEX®
  • Type
  H1Z2Z2-K
  • Norme
  EN 50618:2014

Construction

  • Câble photovoltaique monoconducteur à faible fumée, sans halogène, isolation réticulée et gaine extérieure. 
  • String Harness selon IEC 62548 Photovoltaic (PV) arrays - Design requirements.

Utilisation recommandée

  • Energies renouvelables: fermes solaires.
  • Conçus pour utilisation permanente à l'extérieur et à l'intérieur. 
  • En installation fixe ou mobile, dans des chemins de câbles et tuyaux.
  • Ces câbles ont un comportement approprié dans l'eau : tests des annexes D et E des câbles H07RN8-F AD8 (100 jours à 50°C sous 1 kV AC sans claquage) et test supplémentaire de 1,5 ans dans l'eau chaud (85 °C) sous 1 kV DC sans claquage. Ils conviennent aux installations immergées avec une période d'immersion cumulée maximale de 6 mois par an.

     

Températures d'utilisation

Temperature ambiante = 60°C

Température maximale à l'âme = 120°C

TECHNICAL INFORMATION (1/3)

 

Peroxide Crosslinked Material

Halogen Free Material

Cable insulation and jacket are both based on crosslinked polymers. Crosslinking is performed using peroxide technology. It means that the polymer macromolecular chains are physically bound by chemical links. The peroxide crosslinking is one of the most efficient ways to crosslink because it allows a crosslinking on a melt polymer, leading to a homogeneous network and a high density of links among the material thickness.

 

Advantages

  • Infusible material (no more melting),
  • Increased resistance to ageing: better thermal ageing, UV resistance, better resistance to chemicals…,
  • Better mechanical properties (impact, abrasion…),
  • High integrity to support overload or short circuit.

Fig: The peroxide molecule decomposition leads to the formation of chemical bonds between polymer chains. After crosslinking, a three-dimensional network is obtained. The polymer chains are no more capable to slip among themselves and an infusible material is obtained with improved properties.

Halogen based materials are widely used in cable industry with PVC and flame retardant additives. Halogens are a specific family of chemical elements: Fluorine (F), Chlorine (Cl), Bromine (Br), Iodine (I), Astatine (At).

These elements are well-known to bring high performances regarding fire retardancy. However, they generate during the burning phase a heavy dark smoke with the formation of highly toxic and corrosive gases. Our Energyflex® cables are totally free of these elements.

 

Halogen content by Ion Chromatography

Fig: A piece of material is burned in a tube and the emitted gases are carried and trapped for analysis. For a precise dosage of these different halogen elements, ion chromatography allows to separate these elements and to quantify accurately the amount of each species.

 

Corrosivity of smoke

Fig: As seen before, a piece of material is burned and the gases are trapped in a liquid solution to measure the corrosivity of smoke. The pH and conductivity are measured and should be higher than respectively 4.3 and 10 µS/mm.

 

 

 

 

 

 

TECHNICAL INFORMATION (2/3)

Long Term Thermal Endurance

Sunlight Resistance

 

The cable ageing under thermal oxidation leads to the degradation of the polymer material. To predict or at least to estimate what could be the lifetime of a material under thermal ageing, one uses the Arrhenius procedure depicted in the IEC 60216-1 to 4. The main principle is to age the material at high temperatures and then, using the Arrhenius law, to estimate/predict the lifetime at operating temperature (120 or 90°C). 

 

Arrhenius plot

Ageing was performed at 4 different temperatures: 135°C, 150°C, 165°C and 180°C. The line (linear plot) allows to predict the lifetime at 120 and 90°C. The red dots represent the main targets we are looking for, i.e. the 20000h@120°C, 25years@90°C and 40years@90°C. The more the extrapolated line is above the red dots, the more the lifetime is higher than the target.

The obtained extrapolation is well above the targets and thus the estimated lifetime is bigger than 40years@90°C.

##image:101760:center##

Fig: Arrhenius plot of the insulation material. The criterion to determine the time to failure is chosen as a loss of 50% of the initial elongation at break. At this stage, the cable has initiated it degradation but it is not fully degraded.

 

One of the main causes of material ageing regarding photovoltaic application is the exposure to UV (Ultra-Violet) light, also called photo-degradation. The cable ageing under UV light is due to the combination of the temperature and UV irradiation (harmful UV irradiation is mainly between wavelengths 300 and 400 nm on the earth surface).

 

Accelerated ageing

Our jacketing material presents no degradation after 1 month of weathering acc. to the EN 50289-4-17 method A.

##image:101761:center##

Fig: The Xenon lamp generates a spectrum close to the sunlight one. The samples are placed facing the lamp and are submitted to a specific irradiance and temperature to accelerate the UV ageing.

 

Beyond the standard

##image:101762:center##

Fig: Here in our Nexans process, we exceed the test conditions of the EN (4000hours against 720h  and 100W/m² against 43W/m² specified) and we see no change of the mechanical features.

   

TECHNICAL INFORMATION (3/3)

Dynamic Mechanical Performances

Fire/Flame Retardancy

No dynamic mechanical tests are found in the EN 50618 standard because the cables are intended to be used without any dynamic constraints.

As Energyflex® could be used for Tracker systems, we have performed additional tests:

  • Cyclic torsion
  • Cyclic bending

Dynamic behaviour

Dynamic/cyclic mechanical constraints lead to the conductor degradation (copper/aluminium braid degradation). In our case, the cable present very good dynamic properties and still transmit current after 100 000 cycles in both torsion and bending. 

##image:101765:center##

Fig: Torsion cycles: 50N ± 135° 100°/s

##image:101766:center##

Fig: Reverse bending: 100N ± 45° 160°/s

 

Energyflex® cables are HFFR, i.e. Halogen Free Fire Retardant cables. The material is free of halogen and is capable to withstand a flame retardant test according to the EN 60332-1-2. It means that the cable presents a good resistance regarding the flame spread with a very good self-extinguishing behavior.

 

Resistance to flame test

The cable passes the EN 60332-1-2 where 600mm of cable are tested vertically. The flame is applied with a 45° angle and a 1kW burner.

##image:101767:center## 

Fig: Picture of the flame test acc. to EN 60332-1. The flame is applied 1 to 8 minutes depending on the cable diameter. The test is compliant if after the flame application, the flame extinguishes with a burned length comprises between 50 and 540mm. 

Caractéristiques

Caractéristiques

Caractéristiques de construction

Caractéristiques de construction

Nature de l'âme
Cuivre étamé Classe 5 suivant EN 60228
Flexibilité de l'âme
Souple classe 5
Isolation
Mélange élastomère réticulé sans halogène
Gaine extérieure
Mélange élastomère réticulé sans halogène
Sans halogène
IEC 60754-1; IEC 60754-2
Forme de l'âme
Circulaire

Caractéristiques dimensionnelles

Caractéristiques dimensionnelles

Nombre de conducteurs
1

Caractéristiques électriques

Caractéristiques électriques

Tension de service nominale Uo/U (Um)
1.0/1.0 (1.2) kV AC 1.5/1.5 (1.8) kV DC

Caractéristiques d'utilisation

Caractéristiques d'utilisation

Température ambiante d'utilisation, plage
-40 ... 90 °C
Température maximale sur l'âme
120 °C
Température maximale sur l'âme en court circuit
250 °C
Corrosivité des fumées
Faible IEC 60754-2
Densité de fumée dégagée
IEC 61034-1-2
Tenue à l'ozone
EN 50396:2005
Résistance aux intempéries
Excellente
Non propagateur de la flamme
IEC 60332-1
Etanchéité
Test satisfaisant 100 jours immersion dans l'eau à 50°C - EN 50525-2-21 annexes D et E
Résistance aux vibrations
Condition AH 3 (sever industrial conditions) acc. to HD 60364-5-52
Tenue aux UV
EN 50289-4-17 method A, for 720h. Nexans prestige test 4000h

Ressources

Ressources

Documentation

Contactez-nous

Sujets sur lesquels vous souhaitez obtenir plus d'informations :

* Champs obligatoires

Veuillez vérifier votre saisie et réessayer.

Une adresse mail ne peut contenir qu'un seul @

Protection des données personnelles

Vous avez le droit de vous opposer au traitement de vos données personnelles et/ou à leur utilisation à des fins de marketing direct ou à des fins commerciales.

Merci !

Merci de nous avoir contactés. Nous vous contacterons sous peu.

Erreur

Une erreur s'est produite. Veuillez réessayer.

Fermer

Contactez-nous

* Champs obligatoires

Veuillez vérifier votre saisie et réessayer.

Une adresse mail ne peut contenir qu'un seul @

Protection des données personnelles

Vous avez le droit de vous opposer au traitement de vos données personnelles et/ou à leur utilisation à des fins de marketing direct ou à des fins commerciales.

Merci !

Merci de nous avoir contactés. Nous vous contacterons sous peu.

Erreur

Une erreur s'est produite. Veuillez réessayer.

Fermer