This cable is specially designed for Wind Turbines and to be used for the Loop .
 
Maximum torsion stress ± 150°/meter ( ± 100°/meter for 400mm²) 
 - Standard test : 2000 cycles
-  Results : No copper wire broken

The quality of material used for insulation and sheathing and high quality copper conductors make the cables both flexible, durable, resistant to torsion and to high temperatures. Nexans offers more than a decade of experience in the wind energy market. Our expertise makes WINDLINK® cables highly recommended for wind turbines.

 

Main characteristics

  • Frequent torsion: Excellent twisting behaviour
  • Industrial cables resistant to high temperatures
  • Heavy duty for industrial applications
  • Operating voltage up to 1 kV for use in fixed protected installations
  • Temperature on core: 90°C in normal use - 250°C in short circuit
  • Water resistance: AD2, AD6
  • Corrosive and polluting substances resistance: AF3
  • Outdoor use: temporary and permanent
  • Impact resistance: AG2
  • Oil resistant ASTM/IRM 902 and special oils used in wind turbines
  • UV resistant
  • Ozone resistant
  • Fire performance: Flame retardant (IEC 60332-1), Fire retardant (IEC 60332-3-24)
     

 

Design 

1. Conductor
Flexible (fine wire class 5 acc. to IEC/EN 60228)
Annealed plain copper - Optional PET separator on core

2. Insulation
Special cross-linked EI 8 rubber for high temperatures
Optional PET tape on insulation or assembling

3. Sheath
High mechanical performance, oil- and ozone resistant
Special cross-linked EM8 synthetic halogen free rubber (XLEVA class), improved for low temperature behaviour (-40°C)
Colour: black

Complementary technical data for WINDLINK® LV loop rubber cables

Electrical characteristics

Permissible current rating (see table):
Each cable has been tested to the following levels:

  • Permanent temperature of operation on the core 90°C
  • Ambient temperature for indoor installation 30°C

Correction factors for other ambient temperature:
According to IEC 60364-5-52 Table B.52.14

 

Ambient temperature (°C) Correction factor 
10 1.15
15 1.12
20 1.08
25 1.04
30 1
35 0.96
40 0.91
45 0.87
50 0.82
55 0.76
60 0.71

The Voltage drop has been determined with cos φ= 0.8

Short circuit: constant K= 139 for 1 second calculated acc. to IEC 60949 (short circuit temperature +250°C and conductor temperature +90°C)

Usage characteristics

Bending radius:

Mobile use = 6 x External diameter
Static use = 3 x External diameter , if the external diameter < 12mm, 4 x External diameter, if the external diameter >12 mm.

Sheat oil resistance: good in mineral oils, gear and hydraulic oils

  • Mineral oil ASTM/IRM 902, 24h at 100°C
  • Gear box oil Tribol 1710/320 or equiv, 72h at 40°C
  • Hydraulic oil Mobil DTE 13 M or equiv, 72h at 40°C 

 

Caractéristiques

Caractéristiques

Caractéristiques de construction

Caractéristiques de construction

Structure
6 G 1.5
Nature de l'âme
Plain annealed copper
Flexibilité de l'âme
Souple classe 5
Couleur d'isolation
-
Isolation
Cross-linked synthetic elastomer type EI 8
Gaine interne
-
Gaine extérieure
Cross-linked synthetic elastomer type EM 8
Couleur de la gaine
Noir

Caractéristiques dimensionnelles

Caractéristiques dimensionnelles

Section du conducteur
1,5 mm²
Diamètre du conducteur (mm)
1,5 mm
Nombre de conducteurs
6
Epaisseur nominale de l’isolant
0,8 mm
Insulation sheath thickness
- mm
Diamètre sur isolation
3,1 mm
Epaisseur de la gaine interne
- mm
Epaisseur nom. gaine ext.
2,5 mm
Diamètre minimal du câble
- mm
Diamètre maximal du câble
- mm
Outer Diameter as per Standard Min Max
13.4 ... 17.2 mm
Outer diameter acc Windturbines needs Min Max
13.4 ... 16 mm
Poids en cuivre
86,4 kg/km
Masse approximative
295 kg/km

Caractéristiques électriques

Caractéristiques électriques

Résistance du conducteur interne (courant continu)
- Ohm/km
Max. Electrical Resistance AC 60Hz 70°C
- Ohm/km
Intensité admissible à l'air libre, 30°C, pose en trèfle
18 A
Max. Electrical Resistance AC 60Hz 90°C
- Ohm/km
Inductive reactance
- Ohm/km
Perm. current rating in air 30°C - spaced installation
- A
Courant de court-circuit admissible
- kA
Voltage Drop
23,3 V/A.km
Intensité admissible à l air libre
- A
Résistance ohmique max. du conducteur à 20°C
13,3 Ohm/km
Maximum DC resistance of the conductor at 90°C
17,000 Ohm/km
Tension de service nominale Uo/U (Um)
450 / 750 V (600/1000)
Maximum operating voltage
-
Reactance at 50 Hz
0,104 Ohm/km
Tension d'essai
3500 V

Caractéristiques mécaniques

Caractéristiques mécaniques

Mechanical stress
15 N/mm2
Torsion test max. +/- 4 turns for 10 meters
max:150° per meter
Torsion stress
- °/m
Résistance mécanique aux chocs
Bonne
Maximum tensile strength
- N/mm2

Caractéristiques d'utilisation

Caractéristiques d'utilisation

Corrosivité des fumées
-
Densité de fumée dégagée
IEC 61034
Non propagateur de la flamme
-
Résistance aux huiles
Oui
Tenue à l'ozone
-
Température maximale sur l'âme
90 °C
Tenue aux UV
Oui
Température maximale sur l'âme en court circuit
250 °C
Température ambiante d'utilisation, plage
-40 ... 50 °C
Installation temperature, range
- °C
Minimum Bending Radius during installation
- (xD)
Minimum bending radius, static (XD)
-
Etanchéité
AD2 to AD6

Ressources

Ressources

Documentation

Licence USE pdf — 613.8 kB

Information de livraison

Marking

WINDLINK® NEXANS 213 USE< HAR >H07ZZ-F
Nb cores X (or G) S
X = without G/Y
G = with G/Y
S = cross section (mm2)
Week + year of manufacture
meter marking

 

Insulated Cores identification

• 1 core = Black (preferential)
• 2 cores = Brown + Blue
• 3 cores = Green/Yellow + Blue + Brown (G)
Brown + Black + Grey (X S>4mm²)
• 4 cores = Green/Yellow + Brown + Black + Grey (G)
Blue + Brown + Black + Grey (X S 1.5 & 2.5mm²)
• 5 cores = Green/Yellow + Brown + Black + Grey + Blue (G)
• >5 cores = black + white numbers (X) + G/Y (G)

Contactez-nous

Sujets sur lesquels vous souhaitez obtenir plus d'informations :

* Champs obligatoires

Veuillez vérifier votre saisie et réessayer.

Une adresse mail ne peut contenir qu'un seul @

Protection des données personnelles

Vous avez le droit de vous opposer au traitement de vos données personnelles et/ou à leur utilisation à des fins de marketing direct ou à des fins commerciales.

Merci !

Merci de nous avoir contactés. Nous vous contacterons sous peu.

Erreur

Une erreur s'est produite. Veuillez réessayer.

Fermer

Contactez-nous

* Champs obligatoires

Veuillez vérifier votre saisie et réessayer.

Une adresse mail ne peut contenir qu'un seul @

Protection des données personnelles

Vous avez le droit de vous opposer au traitement de vos données personnelles et/ou à leur utilisation à des fins de marketing direct ou à des fins commerciales.

Merci !

Merci de nous avoir contactés. Nous vous contacterons sous peu.

Erreur

Une erreur s'est produite. Veuillez réessayer.

Fermer