Nexans U-1000 RVFV

Products

U-1000 RVFV 2x25 cut to length

Nexans ref. 10013390 - Country ref. 01300270

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 2
  • Conductor cross-section: 25 mm²

 

U-1000 RVFV 3G25 cut to length

Nexans ref. 10013526 - Country ref. 01300470

  • Packaging: Cut to length (m)
  • With Green/Yellow core: Yes
  • With smaller neutral conductor: No
  • Number of cores: 3
  • Conductor cross-section: 25 mm²

 

U-1000 RVFV 3X120 cut to length

Nexans ref. 10041588 - Country ref. 01248567

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 3
  • Conductor cross-section: 120 mm²

 

U-1000 RVFV 3X150 cut to length

Nexans ref. 10014480 - Country ref. 01248568

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 3
  • Conductor cross-section: 150 mm²

 

U-1000 RVFV 3X185 cut to length

Nexans ref. 10020211 - Country ref. 01248569

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 3
  • Conductor cross-section: 185 mm²

 

U-1000 RVFV 3X185+70 cut to length

Nexans ref. 10019992 - Country ref. 01248578

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: Yes
  • Number of cores: 3
  • Conductor cross-section: 185 mm²

 

U-1000 RVFV 3X240 cut to length

Nexans ref. 10090974 - Country ref. 01248570

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 3
  • Conductor cross-section: 240 mm²

 

U-1000 RVFV 3X240+95 cut to length

Nexans ref. 10014481 - Country ref. 01248577

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: Yes
  • Number of cores: 3
  • Conductor cross-section: 240 mm²

 

U-1000 RVFV 3X70 cut to length

Nexans ref. 10091375 - Country ref. 01248571

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 3
  • Conductor cross-section: 70 mm²

 

U-1000 RVFV 3X95 cut to length

Nexans ref. 10014826 - Country ref. 01248572

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 3
  • Conductor cross-section: 95 mm²

 

U-1000 RVFV 3x120+70 cut to length

Nexans ref. 10014022 - Country ref. 01300950

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: Yes
  • Number of cores: 4
  • Conductor cross-section: 120 mm²

 

U-1000 RVFV 3x150+70 cut to length

Nexans ref. 10013993 - Country ref. 01300960

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: Yes
  • Number of cores: 4
  • Conductor cross-section: 150 mm²

 

U-1000 RVFV 3x25 cut to length

Nexans ref. 10013524 - Country ref. 01301170

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 3
  • Conductor cross-section: 25 mm²

 

U-1000 RVFV 3x35 cut to length

Nexans ref. 10013951 - Country ref. 01300480

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 3
  • Conductor cross-section: 35 mm²

 

U-1000 RVFV 3x50 cut to length

Nexans ref. 10013916 - Country ref. 01300490

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 3
  • Conductor cross-section: 50 mm²

 

U-1000 RVFV 3x50+35 cut to length

Nexans ref. 10013944 - Country ref. 01300910

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: Yes
  • Number of cores: 4
  • Conductor cross-section: 50 mm²

 

U-1000 RVFV 3x70+50 cut to length

Nexans ref. 10013907 - Country ref. 01300930

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: Yes
  • Number of cores: 4
  • Conductor cross-section: 70 mm²

 

U-1000 RVFV 3x95+50 cut to length

Nexans ref. 10013909 - Country ref. 01300940

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: Yes
  • Number of cores: 4
  • Conductor cross-section: 95 mm²

 

U-1000 RVFV 4G120 cut to length

Nexans ref. 10024894 - Country ref. 01248859

  • Packaging: Cut to length (m)
  • With Green/Yellow core: Yes
  • With smaller neutral conductor: No
  • Number of cores: 4
  • Conductor cross-section: 120 mm²

 

U-1000 RVFV 4G25 cut to length

Nexans ref. 10013490 - Country ref. 01300670

  • Packaging: Cut to length (m)
  • With Green/Yellow core: Yes
  • With smaller neutral conductor: No
  • Number of cores: 4
  • Conductor cross-section: 25 mm²

 

U-1000 RVFV 4G35 cut to length

Nexans ref. 10014515 - Country ref. 01300685

  • Packaging: Cut to length (m)
  • With Green/Yellow core: Yes
  • With smaller neutral conductor: No
  • Number of cores: 4
  • Conductor cross-section: 35 mm²

 

U-1000 RVFV 4X120 cut to length

Nexans ref. 10048350 - Country ref. 01248573

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 4
  • Conductor cross-section: 120 mm²

 

U-1000 RVFV 4x25 cut to length

Nexans ref. 10013391 - Country ref. 01301270

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 4
  • Conductor cross-section: 25 mm²

 

U-1000 RVFV 4x50 cut to length

Nexans ref. 10013945 - Country ref. 01300690

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 4
  • Conductor cross-section: 50 mm²

 

U-1000 RVFV 4x70 cut to length

Nexans ref. 10013551 - Country ref. 01300700

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 4
  • Conductor cross-section: 70 mm²

 

U-1000 RVFV 4x95 cut to length

Nexans ref. 10013942 - Country ref. 01300710

  • Packaging: Cut to length (m)
  • With Green/Yellow core: No
  • With smaller neutral conductor: No
  • Number of cores: 4
  • Conductor cross-section: 95 mm²

 

U-1000 RVFV 5G25 cut to length

Nexans ref. 10013527 - Country ref. 01300865

  • Packaging: Cut to length (m)
  • With Green/Yellow core: Yes
  • With smaller neutral conductor: No
  • Number of cores: 5
  • Conductor cross-section: 25 mm²

 

U-1000 RVFV 5G35 cut to length

Nexans ref. 10020157 - Country ref. 01300880

  • Packaging: Cut to length (m)
  • With Green/Yellow core: Yes
  • With smaller neutral conductor: No
  • Number of cores: 5
  • Conductor cross-section: 35 mm²

 

Description

Description

Standards

  • Product
    XP C 32-322

Application

These U-1000 RVFV cables are suitable for direct burial without additionnal protection or for installation on cables trays or in ducts where mechanical protection is necessary (bursting risk).

Core stranding

Cores stranded with filler.

Installation

Burried directly in the ground.

Outside on cable trays, within conduits or fixed to walls.

Permissible current and voltage drop are given

a) in free air, sheltered from sun, on cable tray or bracket, on cable ladder, and spaced from the wall, temperature = 30°C.
b) buried with thermal resistivity of the ground 1Km/W, laying depth : 600 mm, temperature = 20°C.

If conditions are differents, apply correction factors from NF C 15-100 standard  or equivalent national standard
 

Voltage drop

Calculated with cosj = 0,8

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare copper
Insulation
XLPE (chemical)
Inner sheath
PVC watertight sheath
Outer sheath
PVC
Sheath colour
Black
Lead free
Yes
Conductor shape
Circular

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Excellent
Cable flexibility
Rigid

Usage characteristics

Usage characteristics

Flame retardant
C2, NF C 32-070
Chemical resistance
Accidental
Weather resistance
Very good
Water proof
Intermittent
Max. conductor temperature in service
90 °C
Operating temperature, range
-10 ... 60 °C
Short-circuit max. conductor temperature
250 °C
Packaging
Cut to length

Resources

Resources

Selling & delivery Information

Marking

U-1000 RVFV NF-USE N° Usine S.Y+ n (x ou G) s mm²

  • n = number of cores
  • s = section in mm²
  • G = with Green-Yellow
  • x = without Green-Yellow

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close