Nexans FR-N1 X6G3-AR PROTECT

Products

Nexans FR-N1X6G3-AR 1x120

Nexans ref. 10593364

  • Packaging: Cut to length (m)
  • Minimum static operating bending radius: 132 mm

 

Nexans FR-N1X6G3-AR 1x150

Nexans ref. 10593365

  • Packaging: Cut to length (m)
  • Minimum static operating bending radius: 144 mm

 

Nexans FR-N1X6G3-AR 1x185

Nexans ref. 10593366

  • Packaging: Cut to length (m)
  • Minimum static operating bending radius: 159 mm

 

Nexans FR-N1X6G3-AR 1x240

Nexans ref. 10593368

  • Packaging: Cut to length (m)
  • Minimum static operating bending radius: 177 mm

 

Nexans FR-N1X6G3-AR 1x300

Nexans ref. 10593369

  • Packaging: Cut to length (m)
  • Minimum static operating bending radius: 192 mm

 

Nexans FR-N1X6G3-AR 1x35

Nexans ref. 10593265

  • Packaging: Cut to length (m)
  • Minimum static operating bending radius: 90 mm

 

Nexans FR-N1X6G3-AR 1x50

Nexans ref. 10593361

  • Packaging: Cut to length (m)
  • Minimum static operating bending radius: 99 mm

 

Nexans FR-N1X6G3-AR 1x70

Nexans ref. 10593362

  • Packaging: Cut to length (m)
  • Minimum static operating bending radius: 108 mm

 

Nexans FR-N1X6G3-AR 1x95

Nexans ref. 10593363

  • Packaging: Cut to length (m)
  • Minimum static operating bending radius: 120 mm

 

Description

Description

Standards

  • Product
    EN 50575; IEC 60228; IEC 60502-1; XP C 32-225
  • Installation
    NF C15-100
  • Test
    EN 50399; EN 60332-1-2; EN IEC 60754-2 (a1)

Application

Nexans FR N1-X6G3-AR PROTECT are non-armored rigid aluminum cables with a Euroclass rating of Cca-s1, d2, a1, complying with the new fire safety regulation for public buildings and high-rise buildings set out in the French decree of 17 May 2024, as well as with NF C15-100-1 standard of August 2024.

These cables can be used in all low-voltage power distribution installations and are particularly suitable for risers in public access buildings and high-rise buildings, as well as for buildings requiring high Fire Safety levels, such as work offices, Data Centers, industrial buildings, tunnels & infrastructures, and all buildings comprising areas with risky external influencing conditions (i.e., BE2 areas).

Installation

FR-N1 X6G3-AR PROTECT cables are primarily intended for indoor applications and can be laid in cable trays, on ladders, inside cable ducts or fixed to walls.

They can also be buried with additional mechanical protection and can be installed outdoor only with specific extra protections (UV resistance, AN3 as per NF C15-100-1).

When pulling cables, all conductors share the load equally. Under no circumstances must the maximum tensile force exceed 5 daN/mm² of the total cross-sectional area.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Stranded class 2
Conductor material
Aluminum
Insulation
XLPE
Outer sheath
HFFR (Halogen Free Flame Retardant)
Conductor shape
Circular
With smaller neutral conductor
No

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Fire retardant
EN 50399
Smoke density
EN/IEC 61034-2
Gases corrosivity
EN IEC 60754-2 (a1)
Max. conductor temperature in service
90 °C
Operating temperature, range
-25 ... 60 °C
Short-circuit max. conductor temperature
250 °C
Minimum installation temperature
0 °C
Bending factor when laying
6 (xD)
Chemical resistance
Accidental
U.V resistance
AN3
Water proof
AD6
Weather resistance
Good

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close