Nexans TWISTAL FR-N1X6G3-AR 4x1x95
Certifications and labels
Nexans TWISTAL FR-N1X6G3-AR 4x1x95
Low fire hazard (LFH/HFFR) rigid & semi-rigid aluminum twisted single-core cables (3P+N), especially designed to make three-phase links with neutral. They are mainly used for electrification of public access buildings (ERP), high-rise buildings (IGH), and industrial applications thanks to their excellent fire behaviour (Euroclass Cca-s1,d2,a1) compliant to NF C15-100.
Nexans FR-N1 X6G3-AR TWISTAL Protect are primarily intended for indoor applications and are available in cross-sections from 35 to 300 mm².
Main benefits
- Fire safety: visibility 5 times higher vs PVC designs, no corrosive gas emission, limited fire propagation
- Reduced carbon footprint: low-carbon aluminum with environmental data available through PEP Ecopassport®
- Easy installation: each core is spotted with a color band, The twisted core reduces the number of drums and cables pulling, more flexible and light than a multiconductor.
- Optimum cable sizing: allows to reduce the section of used cables (in parallel circuits)
- Nexans ref. : 10593081
Description
Description
Standards
-
ProductEN 50575; IEC 60228; IEC 60502-1; XP C 32-225
-
InstallationNF C15-100
-
TestEN 50399; EN 60332-1-2; EN IEC 60754-2 (a1)
Application
Fire safety: Nexans FR N1-X6G3-AR TWISTAL PROTECT are assemblies of rigid, non-armored, single-core twisted (3P+N) aluminum cables with a Euroclass rating of Cca-s1, d2, a1, complying with the new fire safety regulation for public buildings and high-rise buildings set out in the French decree of 17 May 2024, as well as with NF C15-100-1 standard of August 2024.
These cables can be used in all low-voltage power distribution installations and are particularly suitable for risers in public access buildings and high-rise buildings, as well as for buildings requiring high Fire Safety levels, such as work offices, Data Centers, industrial buildings, tunnels & infrastructures, and all buildings comprising areas with risky external influencing conditions (i.e., BE2 areas)
Installation
FR-N1 X6G3-AR PROTECT cables are primarily intended for indoor applications and can be laid in cable trays, on ladders, inside cable ducts or fixed to walls.
They can also be buried with additional mechanical protection and can be installed outdoor only with specific extra protections (UV resistance, AN3 as per NF C15-100-1).
When pulling cables, all conductors share the load equally. Under no circumstances must the maximum tensile force exceed 5 daN/mm² of the total cross-sectional area.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Declaration of Performance
- Declaration of Performance n° : 1001375-BEDO-004
- Certification Date : 6/9/26
- AVCP (Assessment and Verification of Constancy of Performance) : System 1+
- Notified body : NB 2658
- Declared performance : Cca-s1,d2,a1