AAAC 148-AL4 Gr-Int
AAAC 148-AL4 Gr-Int
Homogeneous aluminium alloy conductors from bare overhead lines.
Read more- Nexans ref. : 10057060
- Country ref. : 01002054
- EAN : 3427530000756
Description
Description
Standards
- 
                                            ProductEN 50182; IEC 61089
These homogeneous conductors in aluminium alloy show many advantages i.e lightness, high breaking load allowing long spans, simplificity of the accessories and lastly easy recycling. These conductors are suitable for the long spans network.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                                Conductor flexibility
                                                            
                                                            
                                                                - 
                                                            
                                                        
                                                                Conductor material
                                                            
                                                            
                                                                - 
                                                            
                                                        
                                                                Conductor shape
                                                            
                                                            
                                                                - 
                                                            
                                                        
                                                                Type of cable
                                                            
                                                            
                                                                Inner greased Aster 
                                                            
                                                        Dimensional characteristics
Dimensional characteristics
                                                                Conductor cross-section
                                                            
                                                            
                                                                148 mm²
                                                            
                                                        
                                                                Total number of wires
                                                            
                                                            
                                                                19 
                                                            
                                                        
                                                                Wire diameter
                                                            
                                                            
                                                                3.15 mm
                                                            
                                                        
                                                                Bare wire diameter
                                                            
                                                            
                                                                15.8 mm
                                                            
                                                        
                                                                Approximate weight
                                                            
                                                            
                                                                417 kg/km
                                                            
                                                        
                                                                Aluminium (or alloy) area
                                                            
                                                            
                                                                148.1 mm²
                                                            
                                                        
                                                                External lay direction
                                                            
                                                            
                                                                S 
                                                            
                                                        Electrical characteristics
Electrical characteristics
                                                                Max. DC resistance of the conductor at 20°C
                                                            
                                                            
                                                                0.2239 Ohm/km
                                                            
                                                        Mechanical characteristics
Mechanical characteristics
                                                                Elongation coefficient
                                                            
                                                            
                                                                23 10E-6/°C
                                                            
                                                        
                                                                Final modulus of elasticity (MPA)
                                                            
                                                            
                                                                60000 
                                                            
                                                        
                                                                Minimum breaking load
                                                            
                                                            
                                                                48.12 kN
                                                            
                                                        Usage characteristics
Usage characteristics
                                                                Laying operation bending radius
                                                            
                                                            
                                                                474 mm
                                                            
                                                        Resources
Resources
Documentation
                                                    cross section
                                                    jpg — 13.0 kB
                                                
                                                
                                            Selling & delivery Information
The conductors range is substantial and Nexans is able to propose the suitable way.
Our websites
Select your country to find our products and solutions
- 
                        Africa
                        
                        
                        - Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
 
- Americas
- Asia
- Europe
- Oceania
 
					                	   
					                	   
					                	   
					                	   
					                	   
					                	  