Nexans PV AC/DC 1-1,5kV Alu
Certifications and labels
Nexans PV AC/DC 1-1,5kV Alu
Nexans PV AC/DC 1-1,5kV Alu are low voltage cables.
Nexans PV AC/DC 1-1,5kV Alu cables, 100% manufactured in France (plant Jeumont 59), guarantee a minimum 35% reduction in greenhouse gas emissions compared to standard cables.
This offer is built on the guaranteed use of low-carbon aluminium and recycled plastic, as well as the use of renewable or decarbonised energies in manufacturing the cables.
Nexans provides all the environmental data for its products (PEP Ecopassport®).
Nexans PV AC/DC 1-1,5kV Alu 1x120
Nexans ref. 10280784
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 120 mm²
- Voltage drop, 3 conductors: 0.54 V/A.km
- Maximum admissible traction load (Tm): 360 daN
- Minimum dynamic operating bending radius: 240.0 mm
- Minimum static operating bending radius: 120 mm
Nexans PV AC/DC 1-1,5kV Alu 1x120 Reinforced Sheath
Nexans ref. 10280785
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 120 mm²
- Voltage drop, 3 conductors: 0.54 V/A.km
- Maximum admissible traction load (Tm): 360 daN
- Minimum dynamic operating bending radius: 252.0 mm
- Minimum static operating bending radius: 126 mm
Nexans PV AC/DC 1-1,5kV Alu 1x150
Nexans ref. 10280479
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 150 mm²
- Voltage drop, 3 conductors: 0.45 V/A.km
- Maximum admissible traction load (Tm): 450 daN
- Minimum dynamic operating bending radius: 262.0 mm
- Minimum static operating bending radius: 131 mm
Nexans PV AC/DC 1-1,5kV Alu 1x150 Reinforced Sheath
Nexans ref. 10282297
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 150 mm²
- Voltage drop, 3 conductors: 0.45 V/A.km
- Maximum admissible traction load (Tm): 450 daN
- Minimum dynamic operating bending radius: 282.0 mm
- Minimum static operating bending radius: 141 mm
Nexans PV AC/DC 1-1,5kV Alu 1x185
Nexans ref. 10278897
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 185 mm²
- Voltage drop, 3 conductors: 0.38 V/A.km
- Maximum admissible traction load (Tm): 555 daN
- Minimum dynamic operating bending radius: 282.0 mm
- Minimum static operating bending radius: 141 mm
Nexans PV AC/DC 1-1,5kV Alu 1x185 Reinforced Sheath
Nexans ref. 10282298
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 185 mm²
- Voltage drop, 3 conductors: 0.38 V/A.km
- Maximum admissible traction load (Tm): 555 daN
- Minimum dynamic operating bending radius: 292.0 mm
- Minimum static operating bending radius: 146 mm
Nexans PV AC/DC 1-1,5kV Alu 1x240
Nexans ref. 10276621
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 240 mm²
- Voltage drop, 3 conductors: 0.31 V/A.km
- Maximum admissible traction load (Tm): 720 daN
- Minimum dynamic operating bending radius: 310.0 mm
- Minimum static operating bending radius: 155 mm
Nexans PV AC/DC 1-1,5kV Alu 1x240 Reinforced Sheath
Nexans ref. 10280787
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 240 mm²
- Voltage drop, 3 conductors: 0.31 V/A.km
- Maximum admissible traction load (Tm): 720 daN
- Minimum dynamic operating bending radius: 322.0 mm
- Minimum static operating bending radius: 161 mm
Nexans PV AC/DC 1-1,5kV Alu 1x300
Nexans ref. 10278387
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 300 mm²
- Voltage drop, 3 conductors: 0.26 V/A.km
- Maximum admissible traction load (Tm): 900 daN
- Minimum dynamic operating bending radius: 334.0 mm
- Minimum static operating bending radius: 167 mm
Nexans PV AC/DC 1-1,5kV Alu 1x300 Reinforced Sheath
Nexans ref. 10280789
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 300 mm²
- Voltage drop, 3 conductors: 0.26 V/A.km
- Maximum admissible traction load (Tm): 900 daN
- Minimum dynamic operating bending radius: 346.0 mm
- Minimum static operating bending radius: 173 mm
Nexans PV AC/DC 1-1,5kV Alu 1x400
Nexans ref. 10280790
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 400 mm²
- Voltage drop, 3 conductors: 0.22 V/A.km
- Maximum admissible traction load (Tm): 1200 daN
- Minimum dynamic operating bending radius: 376.0 mm
- Minimum static operating bending radius: 188 mm
Nexans PV AC/DC 1-1,5kV Alu 1x400 Reinforced Sheath
Nexans ref. 10282299
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 400 mm²
- Voltage drop, 3 conductors: 0.22 V/A.km
- Maximum admissible traction load (Tm): 1200 daN
- Minimum dynamic operating bending radius: 388.0 mm
- Minimum static operating bending radius: 194 mm
Nexans PV AC/DC 1-1,5kV Alu 1x50
Nexans ref. 10280741
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 50 mm²
- Voltage drop, 3 conductors: 1.23 V/A.km
- Maximum admissible traction load (Tm): 150 daN
- Minimum dynamic operating bending radius: 182.0 mm
- Minimum static operating bending radius: 91 mm
Nexans PV AC/DC 1-1,5kV Alu 1x50 Reinforced Sheath
Nexans ref. 10282294
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 50 mm²
- Voltage drop, 3 conductors: 1.23 V/A.km
- Maximum admissible traction load (Tm): 150 daN
- Minimum dynamic operating bending radius: 196.0 mm
- Minimum static operating bending radius: 98 mm
Nexans PV AC/DC 1-1,5kV Alu 1x70
Nexans ref. 10280742
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 70 mm²
- Voltage drop, 3 conductors: 0.88 V/A.km
- Maximum admissible traction load (Tm): 210 daN
- Minimum dynamic operating bending radius: 204.0 mm
- Minimum static operating bending radius: 102 mm
Nexans PV AC/DC 1-1,5kV Alu 1x70 Reinforced Sheath
Nexans ref. 10282295
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 70 mm²
- Voltage drop, 3 conductors: 0.88 V/A.km
- Maximum admissible traction load (Tm): 210 daN
- Minimum dynamic operating bending radius: 216.0 mm
- Minimum static operating bending radius: 108 mm
Nexans PV AC/DC 1-1,5kV Alu 1x95
Nexans ref. 10280743
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 95 mm²
- Voltage drop, 3 conductors: 0.66 V/A.km
- Maximum admissible traction load (Tm): 285 daN
- Minimum dynamic operating bending radius: 220.0 mm
- Minimum static operating bending radius: 110 mm
Nexans PV AC/DC 1-1,5kV Alu 1x95 Reinforced Sheath
Nexans ref. 10282296
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 1
- Conductor cross-section: 95 mm²
- Voltage drop, 3 conductors: 0.66 V/A.km
- Maximum admissible traction load (Tm): 285 daN
- Minimum dynamic operating bending radius: 232.0 mm
- Minimum static operating bending radius: 116 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x120
Nexans ref. 10282275
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 120 mm²
- Voltage drop, 3 conductors: 0.54 V/A.km
- Maximum admissible traction load (Tm): 1080 daN
- Minimum dynamic operating bending radius: 1034.16 mm
- Minimum static operating bending radius: 517.08 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x120 Reinforced Sheath
Nexans ref. 10282276
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 120 mm²
- Voltage drop, 3 conductors: 0.54 V/A.km
- Maximum admissible traction load (Tm): 1080 daN
- Minimum dynamic operating bending radius: 1086.0 mm
- Minimum static operating bending radius: 543 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x150
Nexans ref. 10282277
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 150 mm²
- Voltage drop, 3 conductors: 0.45 V/A.km
- Maximum admissible traction load (Tm): 1350 daN
- Minimum dynamic operating bending radius: 1127.28 mm
- Minimum static operating bending radius: 563.64 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x150 Reinforced Sheath
Nexans ref. 10282278
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 150 mm²
- Voltage drop, 3 conductors: 0.45 V/A.km
- Maximum admissible traction load (Tm): 1350 daN
- Minimum dynamic operating bending radius: 1158.48 mm
- Minimum static operating bending radius: 579.24 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x185
Nexans ref. 10282279
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 185 mm²
- Voltage drop, 3 conductors: 0.38 V/A.km
- Maximum admissible traction load (Tm): 1665 daN
- Minimum dynamic operating bending radius: 1215.36 mm
- Minimum static operating bending radius: 607.68 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x185 Reinforced Sheath
Nexans ref. 10282280
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 185 mm²
- Voltage drop, 3 conductors: 0.38 V/A.km
- Maximum admissible traction load (Tm): 1665 daN
- Minimum dynamic operating bending radius: 1256.64 mm
- Minimum static operating bending radius: 628.32 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x240
Nexans ref. 10282281
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 240 mm²
- Voltage drop, 3 conductors: 0.31 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1334.16 mm
- Minimum static operating bending radius: 667.08 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x240 Reinforced Sheath
Nexans ref. 10282282
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 240 mm²
- Voltage drop, 3 conductors: 0.31 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1386.0 mm
- Minimum static operating bending radius: 693 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x300
Nexans ref. 10282283
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 300 mm²
- Voltage drop, 3 conductors: 0.26 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1442.88 mm
- Minimum static operating bending radius: 721.44 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x300 Reinforced Sheath
Nexans ref. 10282284
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 300 mm²
- Voltage drop, 3 conductors: 0.26 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1495.0 mm
- Minimum static operating bending radius: 748 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x300+150
Nexans ref. 10286781
- Packaging: Drum (m)
- With smaller neutral conductor: Yes
- Number of cores: 4
- Conductor cross-section: 300 mm²
- Voltage drop, 3 conductors: 0.26 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1543.2 mm
- Minimum static operating bending radius: 771.6 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x400
Nexans ref. 10282285
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 400 mm²
- Voltage drop, 3 conductors: 0.22 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1623.84 mm
- Minimum static operating bending radius: 811.92 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x50
Nexans ref. 10282269
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 50 mm²
- Voltage drop, 3 conductors: 1.23 V/A.km
- Maximum admissible traction load (Tm): 450 daN
- Minimum dynamic operating bending radius: 787.2 mm
- Minimum static operating bending radius: 393.6 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x50 Reinforced Sheath
Nexans ref. 10282270
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 50 mm²
- Voltage drop, 3 conductors: 1.23 V/A.km
- Maximum admissible traction load (Tm): 450 daN
- Minimum dynamic operating bending radius: 847.2 mm
- Minimum static operating bending radius: 423.6 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x70
Nexans ref. 10282271
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 70 mm²
- Voltage drop, 3 conductors: 0.88 V/A.km
- Maximum admissible traction load (Tm): 630 daN
- Minimum dynamic operating bending radius: 855.12 mm
- Minimum static operating bending radius: 427.56 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x70 Reinforced Sheath
Nexans ref. 10282272
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 70 mm²
- Voltage drop, 3 conductors: 0.88 V/A.km
- Maximum admissible traction load (Tm): 630 daN
- Minimum dynamic operating bending radius: 930.72 mm
- Minimum static operating bending radius: 465.36 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x95
Nexans ref. 10282273
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 95 mm²
- Voltage drop, 3 conductors: 0.66 V/A.km
- Maximum admissible traction load (Tm): 855 daN
- Minimum dynamic operating bending radius: 951.6 mm
- Minimum static operating bending radius: 475.8 mm
Nexans PV AC/DC 1-1,5kV Alu 3x1x95 Reinforced Sheath
Nexans ref. 10282274
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 3
- Conductor cross-section: 95 mm²
- Voltage drop, 3 conductors: 0.66 V/A.km
- Maximum admissible traction load (Tm): 855 daN
- Minimum dynamic operating bending radius: 1003.68 mm
- Minimum static operating bending radius: 501.84 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x120
Nexans ref. 10282231
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 120 mm²
- Voltage drop, 3 conductors: 0.54 V/A.km
- Maximum admissible traction load (Tm): 1440 daN
- Minimum dynamic operating bending radius: 1159.2 mm
- Minimum static operating bending radius: 579.6 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x120 Reinforced Sheath
Nexans ref. 10280791
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 120 mm²
- Voltage drop, 3 conductors: 0.54 V/A.km
- Maximum admissible traction load (Tm): 1440 daN
- Minimum dynamic operating bending radius: 1216.8 mm
- Minimum static operating bending radius: 608.4 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x150
Nexans ref. 10282230
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 150 mm²
- Voltage drop, 3 conductors: 0.45 V/A.km
- Maximum admissible traction load (Tm): 1800 daN
- Minimum dynamic operating bending radius: 880.8 mm
- Minimum static operating bending radius: 440.4 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x150 Reinforced Sheath
Nexans ref. 10280792
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 150 mm²
- Voltage drop, 3 conductors: 0.45 V/A.km
- Maximum admissible traction load (Tm): 1800 daN
- Minimum dynamic operating bending radius: 1298.4 mm
- Minimum static operating bending radius: 649.2 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x185
Nexans ref. 10280793
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 185 mm²
- Voltage drop, 3 conductors: 0.38 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1360.8 mm
- Minimum static operating bending radius: 680.4 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x185 Reinforced Sheath
Nexans ref. 10280794
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 185 mm²
- Voltage drop, 3 conductors: 0.38 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1408.8 mm
- Minimum static operating bending radius: 704.4 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x240
Nexans ref. 10276644
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 240 mm²
- Voltage drop, 3 conductors: 0.31 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1495.2 mm
- Minimum static operating bending radius: 747.6 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x240 Reinforced Sheath
Nexans ref. 10280795
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 240 mm²
- Voltage drop, 3 conductors: 0.31 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1552.8 mm
- Minimum static operating bending radius: 776.4 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x300
Nexans ref. 10282229
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 300 mm²
- Voltage drop, 3 conductors: 0.26 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1617.6 mm
- Minimum static operating bending radius: 808.8 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x300 Reinforced Sheath
Nexans ref. 10286868
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 300 mm²
- Voltage drop, 3 conductors: 0.26 V/A.km
- Maximum admissible traction load (Tm): 2000 daN
- Minimum dynamic operating bending radius: 1680.0 mm
- Minimum static operating bending radius: 840 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x50
Nexans ref. 10282266
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 50 mm²
- Voltage drop, 3 conductors: 1.23 V/A.km
- Maximum admissible traction load (Tm): 600 daN
- Minimum dynamic operating bending radius: 880.8 mm
- Minimum static operating bending radius: 440.4 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x50 Reinforced Sheath
Nexans ref. 10282267
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 50 mm²
- Voltage drop, 3 conductors: 1.23 V/A.km
- Maximum admissible traction load (Tm): 600 daN
- Minimum dynamic operating bending radius: 950.4 mm
- Minimum static operating bending radius: 475.2 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x70
Nexans ref. 10282264
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 70 mm²
- Voltage drop, 3 conductors: 0.88 V/A.km
- Maximum admissible traction load (Tm): 840 daN
- Minimum dynamic operating bending radius: 984.0 mm
- Minimum static operating bending radius: 492 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x70 Reinforced Sheath
Nexans ref. 10282265
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 70 mm²
- Voltage drop, 3 conductors: 0.88 V/A.km
- Maximum admissible traction load (Tm): 840 daN
- Minimum dynamic operating bending radius: 1020.0 mm
- Minimum static operating bending radius: 510 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x95
Nexans ref. 10282232
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 95 mm²
- Voltage drop, 3 conductors: 0.66 V/A.km
- Maximum admissible traction load (Tm): 1140 daN
- Minimum dynamic operating bending radius: 1065.6 mm
- Minimum static operating bending radius: 532.8 mm
Nexans PV AC/DC 1-1,5kV Alu 4x1x95 Reinforced Sheath
Nexans ref. 10282233
- Packaging: Drum (m)
- With smaller neutral conductor: No
- Number of cores: 4
- Conductor cross-section: 95 mm²
- Voltage drop, 3 conductors: 0.66 V/A.km
- Maximum admissible traction load (Tm): 1140 daN
- Minimum dynamic operating bending radius: 1123.2 mm
- Minimum static operating bending radius: 561.6 mm
Description
Description
Standards
-
ProductIEC 60228; IEC 60502-1
Application
The Nexans PV AC/DC 1-1,5kV Alu cable offers excellent performance and long-term reliability, with a projected lifespan of more than 25 years. It is recommended for use in utility-scale solar power plants, regardless of the architecture chosen.
Universal use
The Nexans PV AC/DC 1-1,5kV Alu cable is suitable for both DC power links with a voltage of 1500V between polarity and ground, and for 800V AC power links with respect to high phase/ground voltage rises following the use of an anti-PID* device or an impeding neutral regime.
PID* : Potential Induced Deterioration (of PV panels)
The Nexans PV AC/DC 1-1,5kV Alu cable is available in two versions :
- version for above ground installations,
- version with reinforced sheath for direct buried installations depending on local specifications. In this case, we recommend mechanical laying with sand bedding in the trench.
Design
- Single core cable with aluminum conductor
- XLPE insulation
- PVC outer-sheath or reinforced PVC outer-sheath
(insulation thickness and dielectric test according to IEC 60502-1, LCIE test report n°159694-732611)
Electrical characteristics
Maximum current according to NF C15-100 for cable laid alone:
a) in the open air, sheltered from the sun, on cable trays or cable brackets, cable ladders, and spaced from the wall
b) buried (according to NF C15-100 and UTE C15-520 rules) in a soil with termal resistivity of 1 K.m/W, laying depth: 600 mm
The ampacity and voltage drop values (for cos φ = 0.8 et F = 50Hz) mentioned in the tables are those of a three-phase link.
If the conditions are different, apply the correction factors ot the NF C15-100 standard.
Low carbon offer
Low carbon at a glance
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania