IEC 60502-1 Hypron® Unarmoured Fire retardant
IEC 60502-1 Hypron® Unarmoured Fire retardant
- 0.6/1 kV Power and control cables
- Lead free
- Aliphatic and aromatic hydrocarbons resistant
IEC 60502-1 HYPRON® Unarmoured 1 x 25
Nexans ref. 10121595
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 25 mm²
IEC 60502-1 HYPRON® Unarmoured 1 x 35
Nexans ref. 10121596
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 35 mm²
IEC 60502-1 HYPRON® Unarmoured 1 x 50
Nexans ref. 10121597
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 50 mm²
IEC 60502-1 HYPRON® Unarmoured 1 x 70
Nexans ref. 10121598
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 70 mm²
IEC 60502-1 HYPRON® Unarmoured 1 x 95
Nexans ref. 10121599
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 95 mm²
IEC 60502-1 HYPRON® Unarmoured 1 x 120
Nexans ref. 10121600
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 120 mm²
IEC 60502-1 HYPRON® Unarmoured 1 x 150
Nexans ref. 10121601
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 150 mm²
IEC 60502-1 HYPRON® Unarmoured 1 x 185
Nexans ref. 10121602
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 185 mm²
IEC 60502-1 HYPRON® Unarmoured 1 x 240
Nexans ref. 10121603
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 240 mm²
IEC 60502-1 HYPRON® Unarmoured 1 x 300
Nexans ref. 10121604
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 300 mm²
IEC 60502-1 HYPRON® Unarmoured 1 x 400
Nexans ref. 10121605
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 1
- Conductor cross-section: 400 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 1.5*
Nexans ref. 10121606
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 1.5
Nexans ref. 10121607
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 2.5*
Nexans ref. 10121608
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 2.5
Nexans ref. 10121609
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 4*
Nexans ref. 10121610
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 4
Nexans ref. 10121611
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 6
Nexans ref. 10121612
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 6 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 10
Nexans ref. 10121613
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 10 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 16
Nexans ref. 10121614
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 16 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 25
Nexans ref. 10121615
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 25 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 35
Nexans ref. 10121616
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 35 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 50
Nexans ref. 10121617
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 50 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 70
Nexans ref. 10121618
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 70 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 95
Nexans ref. 10121619
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 95 mm²
IEC 60502-1 HYPRON® Unarmoured 2 x 120
Nexans ref. 10121620
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 2
- Conductor cross-section: 120 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 1.5*
Nexans ref. 10121621
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 1.5
Nexans ref. 10121622
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 2.5*
Nexans ref. 10121623
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 2.5
Nexans ref. 10121624
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 4*
Nexans ref. 10121625
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 4
Nexans ref. 10121626
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 6
Nexans ref. 10121627
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 6 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 10
Nexans ref. 10121628
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 10 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 16
Nexans ref. 10121629
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 16 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 25
Nexans ref. 10121630
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 25 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 35
Nexans ref. 10121631
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 35 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 50
Nexans ref. 10121632
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 50 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 70
Nexans ref. 10121633
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 70 mm²
IEC 60502-1 HYPRON® Unarmoured 3 x 95
Nexans ref. 10121634
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 3
- Conductor cross-section: 95 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 1.5*
Nexans ref. 10121635
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 1.5
Nexans ref. 10121636
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 2.5*
Nexans ref. 10121637
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 2.5
Nexans ref. 10121638
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 4*
Nexans ref. 10121639
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 4
Nexans ref. 10121640
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 6
Nexans ref. 10121641
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 6 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 10
Nexans ref. 10121642
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 10 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 16
Nexans ref. 10121643
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 16 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 25
Nexans ref. 10121644
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 25 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 35
Nexans ref. 10121645
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 35 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 50
Nexans ref. 10121646
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 50 mm²
IEC 60502-1 HYPRON® Unarmoured 4 x 70
Nexans ref. 10121647
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 4
- Conductor cross-section: 70 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 1.5*
Nexans ref. 10121648
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 1.5
Nexans ref. 10121649
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 2.5*
Nexans ref. 10121650
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 2.5
Nexans ref. 10121651
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 4*
Nexans ref. 10121652
- Packaging: Cut to length (m)
- Type of conductor: Solid, Class 1
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 4
Nexans ref. 10121653
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 4 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 6
Nexans ref. 10121654
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 6 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 10
Nexans ref. 10121655
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 10 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 16
Nexans ref. 10121656
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 16 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 25
Nexans ref. 10121657
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 25 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 35
Nexans ref. 10121658
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 35 mm²
IEC 60502-1 HYPRON® Unarmoured 5 G 50
Nexans ref. 10121659
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: Yes
- Number of cores: 5
- Conductor cross-section: 50 mm²
IEC 60502-1 HYPRON® Unarmoured 7 x 1.5
Nexans ref. 10121660
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 7
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 7 x 2.5
Nexans ref. 10121669
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 7
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 10 x 1.5
Nexans ref. 10121661
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 10
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 10 x 2.5
Nexans ref. 10121670
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 10
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 12 x 1.5
Nexans ref. 10121662
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 12
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 12 x 2.5
Nexans ref. 10121671
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 12
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 14 x 1.5
Nexans ref. 10121663
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 14
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 14 x 2.5
Nexans ref. 10121672
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 14
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 19 x 1.5
Nexans ref. 10121664
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 19
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 19 x 2.5
Nexans ref. 10121673
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 19
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 24 x 1.5
Nexans ref. 10121665
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 24
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 24 x 2.5
Nexans ref. 10121674
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 24
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 27 x 1.5
Nexans ref. 10121666
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 27
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 27 x 2.5
Nexans ref. 10121675
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 27
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 30 x 1.5
Nexans ref. 10121667
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 30
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 30 x 2.5
Nexans ref. 10121676
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 30
- Conductor cross-section: 2.5 mm²
IEC 60502-1 HYPRON® Unarmoured 37 x 1.5
Nexans ref. 10121668
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 37
- Conductor cross-section: 1.5 mm²
IEC 60502-1 HYPRON® Unarmoured 37 x 2.5
Nexans ref. 10121677
- Packaging: Cut to length (m)
- Type of conductor: Stranded, class 2
- With Green/Yellow core: No
- Number of cores: 37
- Conductor cross-section: 2.5 mm²
Description
Description
Standards
-
ProductIEC 60228
-
TestIEC 60332-3-22
Applications
These power and control cables are used for electricity supply in low voltage installation system, in moist areas and where hydrocarbons may be present. Hypron® offers an alternative to conventional lead covered cable and is an environmental friendly solution.
Design
Conductor:
Solid plain copper: 1.5 to 4 mm²
Stranded plain copper: 1.5 to 630 mm²
Insulation:
Cross-linked polyethylene (XLPE)
Bedding (optional):
Inner sheath acting as a filler with practically zero thickness or assembling polyester tape
Inner covering (optional): inner sheath
Polyvinyl chloride (PVC) Colour black
Screen/sealing barrier:
Tinned copper drain wire, Aluminium/polyethylene tape
Sheath:
High density polyethylene (PE) Colour: black
Special sheath (intermediate sheath):
Polyamide
Outer sheath:
Polyvinyl chloride (PVC) Colour: black. Other colour on request
Core identification
1 core: black
2x to 5G cores: according to HD 308 S2
Above 5 cores: black core printed with white number
Marking
NEXANS 279 XLPE/AL/HDPE/NC/PVC 0.6/1 kV Nber of cores and cross section Cu IEC 60332-3-22(A) MM YYYY Manufacturing number + meter marking.
IEC 60502-1 (design guide-lines),
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Other fire performances IEC 60332-1 or IEC 60332-3-24(C) on request.
Minimum bending radius:
1 core: 15 x outer diameter
Multicores: 17 x outer diameter
To be doubled during laying operations
Cables with reduced neutral and larger cross-section on request