IEC 60502-2 HYPRON® Unarmoured Fire retardant

Products

IEC 60502-2 HYPRON® Unarmoured 1 x 25

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 25

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 25

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 25

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 35

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 35

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 35

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 35

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 50

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 50

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 50

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 50

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 50

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 95

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 95

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 95

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 95

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 95

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 120

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 120

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 120

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 120

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 120

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 150

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 150

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 150

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 150

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 150

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 185

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 185

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 185

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 185

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 185

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 240

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 240

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 240

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 240

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 240

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 300

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 300

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 300

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 300

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 300 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 400

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 400 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 400

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 400 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 400

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 400 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 400

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 400 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 500

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 500 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 500

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 500 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 500

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 500 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 500

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 500 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 630

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 630 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 630

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 630 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 630

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 630 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 1 x 630

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 630 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 25

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 25

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 25

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 35

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 35

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 35

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 35

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 50

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 50

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 50

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 50

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 95

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 95

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 120

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 120

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 150

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 150

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 185

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV

 

IEC 60502-2 HYPRON® Unarmoured 3 x 185

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

Description

Description

Standards

  • Product
    IEC 60228
  • Test
    IEC 60332-3-22 Cat.A

Applications

These power cables are used for electricity supply in medium voltage installation system where chemicals may be present. Hypron® offers an alternative fo conventional lead covered cable and is an environmental friendy solution .

 

Design

Conductor:

Stranded bare copper (class 2)

Semi-conductor

Insulation:

Cross-linked polyethylene (XLPE)

Semi-conductor

Screen:

Copper tape

Bedding (Optional):

An inner sheath acting as a filler with practically zero thickness

Inner sheath:

Polyvinyl chloride (PVC) Colour black

Screen/sealing barrier:

 Aluminium/polyethylene tape

Sheath:

High density polyethylene (PE) Colour: black

Special sheath (intermediate sheath):

Polyamide

Outer sheath:

Polyvinyl chloride (PVC). Colour: red. Other colour on request.

 

Core identification

1 core: natural
3 x: black – green – brown (by tape under copper screen)
 

 

Marking

NEXANS 279 XLPE/PVC/AL/HDPE/NC/PVC VOLTAGE Nber of cores and cross section Cu/Alu IEC 60332-3-22(A) MM YYYY manufacturing number + meter marking

 

Standards

IEC 60502-2 (design guide-lines)

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare copper
Type of conductor
Stranded, class 2
Insulation
XLPE (Cross-linked Polyethylene)
Screen
Copper tape
Inner sheath
PVC
Intermediate sheath
Polyamide
Outer sheath
PVC
Lead free
Yes
Protection
no

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Chemical resistance
Aliphatic and aromatic hydrocarbons resistant
Max. conductor temperature in service
90 °C
Operating temperature, range
-20 ... 60 °C
U.V resistance
Yes

Resources

Resources

Selling & delivery Information


Other fire performances IEC 60332-1 or IEC 60332-3-24(C) on request.


Minimum bending radius:

1 core: 10 x outer diameter
3x: 8 x outer diameter
To be doubled during laying operations


Aluminium conductors available on request

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close