EN 2714-013 MLA

Products

MLA 10 051

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km): -

 

MLA 12 030

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km): -

 

MLA 14 020

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km): 10.9

 

MLA 16 012

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km): -

 

MLA 18 010

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km): -

 

MLA 20 006

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km): -

 

MLA 22 004

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km): -

 

MLA 24 002

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km): -

 

MLA 26 001

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km): -

 

MLB 10 051

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLB 12 030

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLB 14 020

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLB 16 012

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLB 18 010

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLB 20 006

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLB 22 004

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLB 24 002

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLB 26 001

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLC 10 051

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLC 12 030

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLC 14 020

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLC 16 012

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLC 18 010

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLC 20 006

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLC 22 004

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLC 24 002

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLC 26 001

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLD 14 020

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLD 16 012

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLD 18 010

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLD 20 006

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLD 22 004

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLD 24 002

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

MLD 26 001

Nexans ref.

  • Max. DC resistance of the conductor at 20°C (Ohm/km):

 

Description

Description

Standards

  • International
    EN 2267-009; EN 2714-013

 

CORES
1 cores
EN2267-009A
 

SCREEN
Nickel plated copper spiral screen
 

JACKET
Polyimide tape
UV PTFE tape

 

CORES

2, 3 or 4 cores
EN2267-009A
 

SCREEN
Nickel plated copper spiral screen
 

JACKET
Polyimide tape
UV PTFE tap

   
IDENTIFICATION  
              
1 core (MLB) : white execpt code 001: Light Yellow/ code 004: Light Green
  :
   
Marking : EN DRA ++ FRF **
Colour of marking : White for red and green core,
    Green for blue and yellow core
   
Jacket  
Colour : White except code 002, 006, 012 : Light Blue
Marking : EN xxx ++ FRF **
Colour of marking : Green
      xxx : Short designation (MLA, MLB, MLC, MLD)
      ++ : AWG
     FR : Country of Origin (FR = France)
     F : Manufacturer (F = Nexans)
     ** : Year of manufacturing (ie 14 = 2014

Characteristics

Characteristics

Electrical characteristics

Electrical characteristics

Maximal operating frequency
0.002 MHz
Operating Voltage Vo DC
28 V
Operating voltage between phase and neutral
115 V
Operating voltage between phases
200 V

Usage characteristics

Usage characteristics

Operating temperature, range
-55 ... 260 °C
Oil resistance
Very good resistance to aircraft fluids
Arc tracking resistant
Yes

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close