NF F 55-625 (K25) 1 core 1000V or 1800V Cl5
CPR B2ca-s1a, d0, a1

Products

NF F 55-625 (K25) 1800 V 1x16 B2ca-s1a, d0, a1

Nexans ref. 10270837

  • Conductor cross-section: 16 mm²
  • Maximum outer diameter: 15.5 mm
  • Approximate weight: 351 kg/km

 

NF F 55-625 (K25) 1800 V 1x240 B2ca-s1a, d0, a1

Nexans ref. 10270835

  • Conductor cross-section: 240 mm²
  • Maximum outer diameter: 34.0 mm
  • Approximate weight: 2715 kg/km

 

Description

Description

Standards

  • International
    EN 50575; IEC 60228
  • National
    NF F 55-625; NF F 55-625

Application

 These cables are used for fixed power or lighting installations (1000 V) and fixed traction circuits (1800 V) in tunnels and underground stations.

Fire resistance

  • Flame retardant: According to RATP K20 specification
  • Fire retardant: According to RATP K20 specification
  • Low smoke: According to RATP K20 specification
  • Without Halogene: According to RATP K20 specification
  • Low Toxicity: According to RATP K20 specification
  • Low Corrosivity: According to RATP K20 specification

Design

  • Conductor : Flexible bare copper 5
  • Insulation : Cross-linked polyethylene (XLPE)
  • Outer sheath : Polyolefine without halogen, Colour : black

Marking

1000 V cables: 1000 - Nber of cores &  cross-section - S - SH - NF F 55-625 - NEXANS 279 - WW - YY  - B2ca-s1a, d0, a1 Manufacturing number  DoP:1000291-FRME + metric marking

1800 V cables: 1800 - Nber of cores &  cross-section - S - SH - NF F 55-625 - NEXANS 279 - WW - YY  - B2ca-s1a, d0, a1 Manufacturing number  DoP:1000291-FRME + metric marking

Core Identification

 Black

 

 

 

Reaction to fire: B2ca-s1a, d0, a1

 

COMPLEMENT

Bending Radius

  • r = 8 x maximum outer diameter

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Plain copper
Type of conductor
Flexible, Classe 5
Insulation
XLPE (Cross-linked Polyethylene)
Outer sheath
Halogen free polyolefin
Halogen free
IEC/EN 60754-1
With Green/Yellow core
No

Usage characteristics

Usage characteristics

Flame retardant
IEC/EN 60332-1-2
Smoke density
IEC 61034-2 & EN 61034-2
Gases corrosivity
IEC/EN 60754-2
Max. conductor temperature in service
90 °C
Operating temperature, range
-20 ... 60 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close