FLAMEX® EN 50264-3-2 MMS 600V

Products

FLAMEX EN 50264-3-2 600V 2x1.5 MMS

Nexans ref. 79466252

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 2
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 7.7 mm
  • Maximum outer diameter: 8.6 mm
  • Approximate weight: 97 kg/km

 

FLAMEX EN 50264-3-2 600V 3x1.5 MMS

Nexans ref. 79466253

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 8.3 mm
  • Maximum outer diameter: 9.3 mm
  • Approximate weight: 120 kg/km

 

FLAMEX EN 50264-3-2 600V 3G1.5 MMS

Nexans ref. 79466203

  • Packaging: Drum (1000m)
  • With Green/Yellow core: Yes
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 8.3 mm
  • Maximum outer diameter: 9.3 mm
  • Approximate weight: 120 kg/km

 

FLAMEX EN 50264-3-2 600V 4G1.5 MMS

Nexans ref. 79466204

  • Packaging: Drum (1000m)
  • With Green/Yellow core: Yes
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 9.8 mm
  • Maximum outer diameter: 10.5 mm
  • Approximate weight: 148 kg/km

 

FLAMEX EN 50264-3-2 600V 4x1.5 MMS

Nexans ref. 79466254

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 9.8 mm
  • Maximum outer diameter: 10.5 mm
  • Approximate weight: 148 kg/km

 

FLAMEX EN 50264-3-2 600V 5x1.5 MMS

Nexans ref. 79466255

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 5
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 10.5 mm
  • Maximum outer diameter: 11.5 mm
  • Approximate weight: 192 kg/km

 

FLAMEX EN 50264-3-2 600V 6x1.5 MMS

Nexans ref. 79466256

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 6
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 11.5 mm
  • Maximum outer diameter: 12.5 mm
  • Approximate weight: 226 kg/km

 

FLAMEX EN 50264-3-2 600V 7x1.5 MMS

Nexans ref. 79466257

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 7
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 12.5 mm
  • Maximum outer diameter: 13.5 mm
  • Approximate weight: 267 kg/km

 

FLAMEX EN 50264-3-2 600V 10x1.5 MMS

Nexans ref. 79466260

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 10
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 14.5 mm
  • Maximum outer diameter: 15.5 mm
  • Approximate weight: 336 kg/km

 

FLAMEX EN 50264-3-2 600V 2x2.5 MMS

Nexans ref. 79466352

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 2
  • Conductor cross-section: 2.5 mm²
  • Minimum outer diameter: 9.3 mm
  • Maximum outer diameter: 8.3 mm
  • Approximate weight: 119 kg/km

 

FLAMEX EN 50264-3-2 600V 3x2.5 MMS

Nexans ref. 79466353

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Minimum outer diameter: 9.5 mm
  • Maximum outer diameter: 10.4 mm
  • Approximate weight: 149 kg/km

 

FLAMEX EN 50264-3-2 600V 3G2.5 MMS

Nexans ref. 79466303

  • Packaging: Drum (1000m)
  • With Green/Yellow core: Yes
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Minimum outer diameter: 9.5 mm
  • Maximum outer diameter: 10.4 mm
  • Approximate weight: 149 kg/km

 

FLAMEX EN 50264-3-2 600V 4x2.5 MMS

Nexans ref. 79466354

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Minimum outer diameter: 10.7 mm
  • Maximum outer diameter: 11.7 mm
  • Approximate weight: 205 kg/km

 

FLAMEX EN 50264-3-2 600V 4G2.5 MMS

Nexans ref. 79466304

  • Packaging: Drum (1000m)
  • With Green/Yellow core: Yes
  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Minimum outer diameter: 10.7 mm
  • Maximum outer diameter: 11.7 mm
  • Approximate weight: 205 kg/km

 

FLAMEX EN 50264-3-2 600V 5G2.5 MMS

Nexans ref. 79466305

  • Packaging: Drum (1000m)
  • With Green/Yellow core: Yes
  • Number of cores: 5
  • Conductor cross-section: 2.5 mm²
  • Minimum outer diameter: 11.4 mm
  • Maximum outer diameter: 12.4 mm
  • Approximate weight: 247 kg/km

 

FLAMEX EN 50264-3-2 600V 7x2.5 MMS

Nexans ref. 79466357

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 7
  • Conductor cross-section: 2.5 mm²
  • Minimum outer diameter: 14.0 mm
  • Maximum outer diameter: 15.0 mm
  • Approximate weight: 358 kg/km

 

FLAMEX EN 50264-3-2 600V 3x4 MMS

Nexans ref. 79466453

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 3
  • Conductor cross-section: 4 mm²
  • Minimum outer diameter: 11.5 mm
  • Maximum outer diameter: 12.5 mm
  • Approximate weight: 226 kg/km

 

FLAMEX EN 50264-3-2 600V 5x4 MMS

Nexans ref. 79466454

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Minimum outer diameter: 14.0 mm
  • Maximum outer diameter: 15.0 mm
  • Approximate weight: 298 kg/km

 

FLAMEX EN 50264-3-2 600V 3x6 MMS

Nexans ref. 79466653

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Minimum outer diameter: 13.0 mm
  • Maximum outer diameter: 14.0 mm
  • Approximate weight: 304 kg/km

 

FLAMEX EN 50264-3-2 600V 4G6 MMS

Nexans ref. 79466654

  • Packaging: Drum (1000m)
  • With Green/Yellow core: Yes
  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Minimum outer diameter: 15.0 mm
  • Maximum outer diameter: 14.0 mm
  • Approximate weight: 383 kg/km

 

FLAMEX EN 50264-3-2 600V 3x10 MMS

Nexans ref. 79466713

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 3
  • Conductor cross-section: 10 mm²
  • Minimum outer diameter: 17.0 mm
  • Maximum outer diameter: 18.0 mm
  • Approximate weight: 529 kg/km

 

FLAMEX EN 50264-3-2 600V 4x10 MMS

Nexans ref. 79466714

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 4
  • Conductor cross-section: 10 mm²
  • Minimum outer diameter: 18.2 mm
  • Maximum outer diameter: 19.2 mm
  • Approximate weight: 657 kg/km

 

FLAMEX EN 50264-3-2 600V 6x10 MMS

Nexans ref. 79466716

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 6
  • Conductor cross-section: 10 mm²
  • Minimum outer diameter: 20.5 mm
  • Maximum outer diameter: 22.0 mm
  • Approximate weight: 927 kg/km

 

FLAMEX EN 50264-3-2 600V 3x16 MMS

Nexans ref. 79466733

  • Packaging: Drum (1000m)
  • With Green/Yellow core: No
  • Number of cores: 3
  • Conductor cross-section: 16 mm²
  • Minimum outer diameter: 20.0 mm
  • Maximum outer diameter: 21.3 mm
  • Approximate weight: 782 kg/km

 

Description

Description

Standards

  • International
    EN 45545 - HL3; EN 50264-3-2; IEC 60228

FLAMEX® EN 50264-3-2 600V MMS multicores shielded power and control cables are used for protected installations where enhanced electrical screening (EMC) is required. This product range is recommended for installations and connections in narrow spaces where an optimal bending radius is required. FLAMEX® cables are designed to withstand tough working conditions (oil, ozone, temperature variation, etc.). 120°C conductor temperature is allowed for a 20,000 hours cumulative working time.

 

DESIGN

1. Conductor
Flexible stranded tinned copper class 5 acc. to IEC 60228
Optional halogen-free separator tape

2. Insulation
Cross-linked compound type El 109 acc. to EN 50264-1
Colour: black (or green/yellow if cable type is G)
Assembly (option): halogen free foil could be served

3. Screen
Copper wire braid acc. to EN 50264-3-2, halogen-free separator

4. Outer sheath
Cross-linked compound type EM 104 acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black

 

Example of marking: FLAMEX EN 50264-3-2 600V n X (or G) ... (mm²) MM S (N)HXCSLOE I NEXANS I WW-YYYY

 

FIRE SAFETY

FLAMEX® EN 50264-3-2 600V MMS multicores shielded power and control cables are conform to EN 45545-2 HL3

 

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 4 x outer cable diameter
    • For installation and occasional movements: 8 x outer cable diameter

 

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Flexible class 5
Insulation
Cross-linked compound
Screen
Tinned copper braid
Outer sheath
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
EN 60332-3-24; EN 60332-3-25
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Electro magnetic interference resistance
Yes
Operating temperature, range
-40 ... 90 °C
Max. conductor temperature in service
90 °C
Overload maximum core temperature
120 °C
Chemical resistance
Excellent
Ozone resistance
Yes
U.V resistance
Yes

Resources

Resources

Documentation

xls — 0 B
xls — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close