FLAMEX® PANTO LEAD-FREE 185²

Description

Description

Standards

  • International
    EN 45545-2 (HL3); EN 50264-1; IEC 60502

     Applications

For inside and outside use in railway vehicles. Installation in cable ducts or tubes.

Current-carrying capacity acc. to EN 50343. Satisfies performance requirements to acc. to EN 45545-2 - HL3.

Available on request: HV loop, completely pre-assembled flexible cables with plugs and sealing ends, electrically tested.

Conductor temperature: -40°C / +90°C / +120°C

 

Design

1.  Conductor 
     Flexible stranded tinned copper, class 5 acc. to IEC 60228


2.  Inner conductive layer 
     Conductive rubber

3.  Insulation 
     Cross-linked compound type EI 110 acc. to EN 50264-1


4. Outer conductive layer 
    Conductive rubber (thermo-strip)

5. Screen 
   
Conductive tape
    Tinned single wires with separator

6. Outer sheath 
    Cross-linked compound type EM104  acc. to EN 50264-1
    Oil, diesel, ozone and UV resistant
    Colour: black

 

Cable marking

Ink marking white e.g.:

FLAMEX VDE-Reg.-Nr. 7969  (N)TMCGCHXOE 1x95mm² RF/16 25/45 kV

WW/YYYY

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Flexible class 5
Insulation
Cross-linked compound
Outer sheath
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2
Sheath colour
Black
Material of the inner semi-conductor
conductive rubber
Material of the external semi-conductor
Conductive rubber
Screen
Copper wires

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
185 mm²
Screen section
25 mm²
Diameter over external semi-conductor
37.0 mm
Minimum outer diameter
42.0 mm
Maximum outer diameter
44.0 mm
Approximate weight
3600 kg/km
Number of cores
-

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
26 / 45 (54) kV
Maximum operating voltage
32 kV

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
IEC 60332-3-24
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-40 ... 90 °C
Fire load
- kWh/m
Minimum operating temperature
- °C
Short-circuit max. conductor temperature
200 °C
Bending factor when laying
10 (xD)
Bending factor when installed
6 (xD)
Oil resistance
Yes
Ozone resistance
Yes
U.V resistance
Yes

Resources

Resources

Documentation

xls — 0 B
xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close