TX® (I) 150/250(300) V

Products

TX® (I) 150/250V 2P0.75

Nexans ref. 10167495

  • Packaging: Cut to length (m)
  • Number of pairs: 2
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 9.4 mm
  • Maximum outer diameter: 11.0 mm
  • Approximate weight: 102 kg/km

 

TX® (I) 150/250V 4P0.75

Nexans ref. 10167499

  • Packaging: Cut to length (m)
  • Number of pairs: 4
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 11.0 mm
  • Maximum outer diameter: 12.5 mm
  • Approximate weight: 150 kg/km

 

TX® (I) 150/250V 7P0.75

Nexans ref. 10167501

  • Packaging: Cut to length (m)
  • Number of pairs: 7
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 13.0 mm
  • Maximum outer diameter: 15.0 mm
  • Approximate weight: 244 kg/km

 

TX® (I) 150/250V 10P0.75

Nexans ref. 10008302

  • Packaging: Cut to length (m)
  • Number of pairs: 10
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 16.0 mm
  • Maximum outer diameter: 18.0 mm
  • Approximate weight: 350 kg/km

 

TX® (I) 150/250V 14P0.75

Nexans ref. 10223450

  • Packaging: Cut to length (m)
  • Number of pairs: 14
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 19.0 mm
  • Maximum outer diameter: 21.5 mm
  • Approximate weight: 483 kg/km

 

TX® (I) 150/250V 19P0.75

Nexans ref. 10008304

  • Packaging: Cut to length (m)
  • Number of pairs: 19
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 20.5 mm
  • Maximum outer diameter: 23.5 mm
  • Approximate weight: 650 kg/km

 

TX® (I) 150/250V 24P0.75

Nexans ref. 10045554

  • Packaging: Cut to length (m)
  • Number of pairs: 24
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 23.5 mm
  • Maximum outer diameter: 26.5 mm
  • Approximate weight: 840 kg/km

 

TX® (I) 150/250V 37P0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: 37
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 27.5 mm
  • Maximum outer diameter: 31.0 mm
  • Approximate weight: 1160 kg/km

 

TX® (I) 150/250V 2T0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 2
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 11.0 mm
  • Maximum outer diameter: 12.5 mm
  • Approximate weight: 160 kg/km

 

TX® (I) 150/250V 4T0.75

Nexans ref. 10167500

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 4
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 12.0 mm
  • Maximum outer diameter: 14.0 mm
  • Approximate weight: 203 kg/km

 

TX® (I) 150/250V 7T0.75

Nexans ref. 10167503

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 7
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 15.5 mm
  • Maximum outer diameter: 18.0 mm
  • Approximate weight: 335 kg/km

 

TX® (I) 150/250V 10T0.75

Nexans ref. 10203711

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 10
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 18.0 mm
  • Maximum outer diameter: 20.5 mm
  • Approximate weight: 464 kg/km

 

TX® (I) 150/250V 2P1.5

Nexans ref. 10046224

  • Packaging: Cut to length (m)
  • Number of pairs: 2
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 11.5 mm
  • Maximum outer diameter: 13.5 mm
  • Approximate weight: 190 kg/km

 

TX® (I) 150/250V 4P1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: 4
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 13.5 mm
  • Maximum outer diameter: 15.5 mm
  • Approximate weight: 270 kg/km

 

TX® (I) 150/250V 7P1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: 7
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 16.5 mm
  • Maximum outer diameter: 19.0 mm
  • Approximate weight: 440 kg/km

 

TX® (I) 150/250V 10P1.5

Nexans ref. 10227431

  • Packaging: Cut to length (m)
  • Number of pairs: 10
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 19.5 mm
  • Maximum outer diameter: 22.5 mm
  • Approximate weight: 581 kg/km

 

TX® (I) 150/250V 14P1.5

Nexans ref. 10046185

  • Packaging: Cut to length (m)
  • Number of pairs: 14
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 22.5 mm
  • Maximum outer diameter: 25.5 mm
  • Approximate weight: 820 kg/km

 

TX® (I) 150/250V 19P1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: 19
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 26.0 mm
  • Maximum outer diameter: 29.0 mm
  • Approximate weight: 1020 kg/km

 

TX® (I) 150/250V 37P1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: 37
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 35.0 mm
  • Maximum outer diameter: 38.5 mm
  • Approximate weight: 2010 kg/km

 

TX® (I) 150/250V 2T1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 2
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 13.5 mm
  • Maximum outer diameter: 15.5 mm
  • Approximate weight: 260 kg/km

 

TX® (I) 150/250V 4T1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 4
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 15.0 mm
  • Maximum outer diameter: 17.0 mm
  • Approximate weight: 350 kg/km

 

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-360; IEC 60092-376
  • Test
    IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 61034

Application

TX® (I) 150/250 V  overall and individually screened twisted pair cables are used for telecommunication and instrumentation purposes. These cables show strong protection aganist cross-talk and result into a good compromise between TX®(C) and TCX®(C)  cables against external electromagnetic disturbances. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

Design

  1. Conductor
    Stranded bare copper class 2
     
  2. Insulation
    XLPE (Cross-linked polyethylene
     
  3. Individual screen
    Alu/polyester tape with a tinned copper drain wire
     
  4. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour : grey
     

Marking

NEXANS 279 TX(I) Nber of pairs/triads & cross-section 150/250V 90C IEC 60092-376 IEC 60332-3-22 Cat.A WW YYYY *CE* Manufacturing n° + metric marking

Core identification

Pair: white / blue with printed pair number
Triad: white / blue / red with printed triad number

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Conductor material
Bare copper
Insulation
XLPE (Cross-linked Polyethylene)
Individual screen
Aluminium / Polyester tape
Drain wire
Tinned copper
Outer sheath
Polyolefin
Sheath colour
Grey

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Flame retardant
IEC 60332-1
Gases corrosivity
IEC 60754-2
Smoke density
IEC 61034
Electro magnetic interference resistance
Yes
Max. conductor temperature in service
90 °C
Operating temperature, range
-30 ... 80 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close