MPRXCX FLEXISHIP 1.8/3kV 3x35

Description

Description

Standards

  • International
    IEC 60092-350; IEC 60092-353; IEC 60092-360; IEC 60228; IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

MPRXCX® FLEXISHIP®   1.8/3 kV armoured power cables are used for equipment in medium voltage areas where enhanced mechanical protection and electrical screening (EMC) is required. These products are recommended for installations and connections in narrow spaces where an optimal bending radius is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.
 

Design

  1. Conductor
    Flexible bare copper, class 5
     
  2. Insulation
    XLPE (cross-linked polyethylene) 
     
  3. Inner covering
    Lapped or extruded
     
  4. Armouring
    Bare copper braid 
     
  5. Outer sheath
    Polyolefin SHF1 (SHF2 on request)
    Colour: red

Marking

I NEXANS I MPRXCX  FLEXISHIP  1.8/3 kV "n" x "s" mm2  90°C IEC 60092-353
IEC 60332-3-22 Cat.A  "ww/yy" + metric marking

 

Core Identification

by colour: black-brown-grey

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Insulation
XLPE
Inner sheath
Polyolefin
Armour type
Bare copper braid
Outer sheath
Polyolefin
Halogen free
IEC 60754-1
Sheath colour
Red
Conductor material
Bare copper
Type of conductor
Flexible Bare copper class 5

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
35 mm²
Nominal outer diameter
32.3 mm
Minimum outer diameter
31.0 mm
Maximum outer diameter
34.5 mm
Approximate weight
2005 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
1.8 / 3 (3.6) kV
Permissible current rating in open air
110 A

Mechanical characteristics

Mechanical characteristics

Corrosivity
IEC 60754-2

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3-22
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Standard
IEC
Operating temperature, range
-30 ... 80 °C
Electro magnetic interference resistance
Yes

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.