SIWO-KUL D30 1x150 1,1 kV YE

Description

Description

Standards

  • Product
    CSA C22.2 N° 210-05; IEC 60228; UL 758
  • Installation
    IEC 60092
  • Test
    IEC 60331; IEC 60332-1; IEC 60332-3-22; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034

Applications

The SIWO-KUL® D30 1.1/1.5 kV cable range is specifically developed for:

  • Connection of windings in rotating machines and transformers with thermal insulation class F and H
  • Wiring of power cabinets, converters, and motor controls
  • Industrial installations exposed to high thermal stress
  • Wind, marine, and railway OEM applications
  • AC/DC interconnections for PV systems and battery storage installations

Key Benefits

  • High flexibility ideal for compact installations
  • Excellent thermal resistance (-55°C to +180°C continuous operation)
  • Compatible with major impregnation resins
  • Resistance to oils, UV radiation, and chemical agents
  • High durability for long service life
  • International approvals and certifications
  • Fire performance

By choosing the SIWO-KUL® range, you opt for a flexible, robust, and durable cable designed to ensure high performance in the most demanding environments.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tinned copper
Conductor flexibility
Flexible class 5
Insulation
Special Silicone
Halogen free
Yes
Outer sheath
Silicon elastomer
Construction type
720 x 0.50

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
150 mm²
Nominal outer diameter
21.7 mm
Approximate weight
1409 kg/km
Conductor diameter
17.6 mm

Electrical characteristics

Electrical characteristics

Operating voltage
1.1 kV
Test voltage
4 kV
Max. DC resistance of the conductor at 20°C
0.132 Ohm/km
Breakdown voltage
10 kV
Breakdown field strength (kV/mm)
> 20
Dielectric constant relative value (indicative)
3.50
Insulation resistance at 20°C
170000 MOhm.km
Loss factor tan d
< 10-2
Minimum insulation resistance
- MOhm.km

Transmission characteristics

Transmission characteristics

Coupling loss 160 MHz (50% / 95%)
dB

Mechanical characteristics

Mechanical characteristics

Elongation at break of insulation (%)
> 250
Minimum Tensile Strength
8 MPa
Permissible pulling forces
0.05 kN/mm²

Usage characteristics

Usage characteristics

Minimum static operating bending radius
127.5 mm
Operating temperature, range
-55 ... 180 °C
Chemical resistance
Good
Maximum operating temperature
180 °C
Minimum operating temperature
-55 °C
Fire resistant
IEC 60331
Oil resistance
Yes
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3-24 (cat C)
Gases corrosivity
IEC 60754-1; IEC 60754-2
Smoke density
IEC 61034
Packaging
Cut to length

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close