NF C 33-209 Aluminium cables

Products

FR-N1XD4-AR 2x16 NFC33209

Nexans ref. 10044008 - Country ref. 01123090

  • Packaging: Cut to length (m)
  • Neutral messenger: None
  • Conductor cross-section: 16 mm²
  • Number of cores: 2

 

FR-N1XD4-AR 2x25 NFC33209

Nexans ref. 10044010 - Country ref. 01123070

  • Packaging: Cut to length (m)
  • Neutral messenger: None
  • Conductor cross-section: 25 mm²
  • Number of cores: 2

 

FR-N1XD4-AR 4x16 NFC33209

Nexans ref. 10044009 - Country ref. 01123290

  • Packaging: Cut to length (m)
  • Neutral messenger: None
  • Conductor cross-section: 16 mm²
  • Number of cores: 4

 

FR-N1XD4-AR 4x25 NFC33209

Nexans ref. 10044011 - Country ref. 01123270

  • Packaging: Cut to length (m)
  • Neutral messenger: None
  • Conductor cross-section: 25 mm²
  • Number of cores: 4

 

FR-N1XD9-AR_AD 2x16 +54.6 NFC33209

Nexans ref. 10057502 - Country ref. 01068260

  • Packaging: Cut to length (m)
  • Neutral messenger: 54.6 mm²
  • Conductor cross-section: 16 mm²
  • Number of cores: 2

 

PHASE TORSADE 1x16AL NFC 33209

Nexans ref. 10057575 - Country ref. 01068253

  • Packaging: Cut to length (m)
  • Neutral messenger: None
  • Conductor cross-section: 16 mm²
  • Number of cores: 1

 

PHASE TORSADE 1x25AL NFC33209

Nexans ref. 10057474 - Country ref. 01068254

  • Packaging: Cut to length (m)
  • Neutral messenger: None
  • Conductor cross-section: 25 mm²
  • Number of cores: 1

 

Description

Description

Standards

  • National
    NF C 11-201; NF C 33-209

Application

ALUMINIUM NF C 33-209 service bundled conductors are used for tributary networks of power buildings and their internal networks.

Characteristics

The bundled conductor cables have aluminum conductors, insulated with XLPE, they have good durability and thermal resistance.

Some other important cable characteristics are :

  • Ultraviolet radiation resistance,
  • Ozone resistance,
  • High dielectric strength,
  • Light and easy to handle.

Installation

The NF C 11-201 standard´s procedures determine the installation procedures for low voltage overhead lines.

These cables are NOT ALLOWED to be buried, even in conduits.

Marking

  • Neutral :

211 NF C 33-209 211 « manufacturing number », « metric marks » ink printed.

  • Phase 1, 2, 3 :

the identification number is printed and embossed on insulation.

  • Pilot wire n°1 : continuous white line is printed on the insulation
  • Pilot wire n°2 : no marking

Electrical characteristics

  • Rated voltage : 0.6/1 kV
  • Test voltage : 4 kV AC
  • Resistance to voltage surges : 1.2/50µs with a positive or negative polarity and a peak value of 20 kV.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Pilot wires
None
Conductor material
Aluminum
Conductor shape
Circular
Insulation
XLPE (chemical)

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/1 kV
Test voltage 1mn 50Hz
4 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
-

Usage characteristics

Usage characteristics

Packaging
Cut to length
Length
- m
Flame retardant
-
Max. conductor temperature in service
- °C

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close