NF C 33-210 standard or antitermite cables

Products

H1-XDV-AR 3x50 +50

Nexans ref. 10057259 - Country ref. 01416750

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Resistant to termites: No

 

H1-XDV-AR 3x50 +50 AT

Nexans ref. 10057410 - Country ref. 01068275

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Resistant to termites: Yes

 

H1-XDV-AS 3x150 +70

Nexans ref. 10044006 - Country ref. 01416780

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Resistant to termites: No

 

H1-XDV-AS 3x240 +95

Nexans ref. 10044007 - Country ref. 01416804

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Resistant to termites: No

 

H1-XDV-AS 3x240 +95 AT

Nexans ref. 10057264 - Country ref. 01068210

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Resistant to termites: Yes

 

H1-XDV-AS 3x95 +50

Nexans ref. 10044005 - Country ref. 01416760

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Resistant to termites: No

 

H1-XDV-AS 3x95 +50

Nexans ref. 10057392 - Country ref. 01272183

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Resistant to termites: Yes

 

Description

Description

Standards

  • National
    NF C 33-210

Application

Low voltage buried cables with standard NF C 33-210 for distribution public networks, three conductors + neutral.

Characteristics

The phase conductors are made of solid or stranded circular (class 2) aluminum depending on type.

The neutral conductor made of Core : aluminum stranded circular (class 2) of solid round and sheathed with lead.

The watertightness between the lead sheath is made with a waterproof material.

Conductors laid up/Filling

The phase conductors and neutral are assembled in a way, which makes them easy to separate to splice with branching wires.

Over phase and neutral conductors, a galvanized steel armour wound in direct the lead sheath. This construction is then sheathed PVC, with high mechanical properties.< p contact>

Filler PVC material only 50 mm2.

Electrical characteristics

  • Rated Voltage : 0.6/1 kV.
  • Test Voltage : 3.5 kV for 15 minutes.
  • resistance of the sheath to voltage surges : 1.2/50 µs with positive or negative polarity and a peak value of 20 kV.

Marking

H1 XDV-AS  "section"  DISTRICABLE ® 211 NFC 33-210 «Manufactured number / manufactured year / metric marks/ manufactured date. »

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Outer sheath
PVC
Conductor material
Aluminum
Conductor flexibility
Stranded class 2
Insulation
XLPE (chemical)
Protection
Watertight textile material
Screen
Two semi-lapped galvanized mild steel tapes
Sheath colour
Black

Dimensional characteristics

Dimensional characteristics

Number of cores
4
Number of phases
3

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Usage characteristics

Usage characteristics

Length
- m
Flame retardant
C2, NF C 32-070

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close